Clinical comparison of I-131 orthoiodohippurate and the kit formulation of Tc-99m mercaptoacetyltriglycine.
- 1 March 1989
- journal article
- research article
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 170 (3) , 721-725
- https://doi.org/10.1148/radiology.170.3.2521734
Abstract
Previous studies in animals and humans have shown that technetium-99m mercaptoacetyltriglycine (MAG3) purified by high-performance liquid chromatography is a renal tubular agent with characteristics similar to those of iodine-131 orthoiodohippurate (OIH). A kit formulation for Tc-99m MAG3 has been developed and compared with I-131 OIH in 17 patients with suspected renal dysfunction and three potential kidney donors. There were no adverse reactions. Tc-99m MAG3 images were of good quality and consistently better than I-131 OIH images. There was no significant difference in the relative renal uptake of Tc-99m MAG3 and I-131 OIH. The 30-minute urinary excretion of Tc-99m MAG3 was 36.4% versus 40.4% for I-131 OIH. The average plasma clearance of Tc-99m MAG3 (138 mL/min .+-. 117) was less than that of I-131 OIH (272 mL/min .+-. 205) (P < .001); however, there was good correlation between the Tc-99m MAG3 and I-131 OIH clearances (r = .87). The volume of distribution of Tc-99m MAG3 (5.96 L .+-. 1.94) was less than that of I-131 OIH (9.41 .+-. 3.73) (P < .001). These characteristics and the advantages of a simple kit formulation should lead to widespread clinical use.This publication has 15 references indexed in Scilit:
- 99mTc-MAG3, a new renal imaging agent: Preliminary results in patientsEuropean Journal of Nuclear Medicine and Molecular Imaging, 1987
- ANIMAL EVALUATION OF TC-99M TRIAMIDE MERCAPTIDE COMPLEXES AS POTENTIAL RENAL IMAGING AGENTS1987
- Evaluation of Tc-99m mercaptoacetyltriglycine in patients with impaired renal function.Radiology, 1987
- COMPARISON OF I-131 OIH AND TC-99M MAG3 RENAL IMAGING IN VOLUNTEERS1986
- SYNTHESIS AND BIOLOGICAL EVALUATION OF TC-99M MAG3 AS A HIPPURAN REPLACEMENT1986
- PEDIATRIC RENAL I-123 ORTHOIODOHIPPURATE DOSIMETRY1985
- SYNTHESIS AND BIOLOGICAL EVALUATION OF TC-99M N,N'-BIS(MERCAPTOACETYL)-2,3-DIAMINOPROPANOATE - A POTENTIAL REPLACEMENT FOR [I-131]-LABELED O-IODOHIPPURATE1982
- CHEMICAL AND BIOLOGICAL STUDIES OF TC-99M N,N'-BIS(MERCAPTOACETAMIDO)-ETHYLENEDIAMINE - A POTENTIAL REPLACEMENT FOR 1-131 LODOHIPPURATE1981
- Individual Renal Plasma Flow Determination in 2 MinutesJournal of Urology, 1976
- Volumes of Distribution and Clearances of Intravenously Injected Creatinine in the DogAmerican Journal of Physiology-Legacy Content, 1955