Simple Q-Measurement of KEK Proton Synchrotron
- 1 June 1977
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 24 (3) , 1818-1820
- https://doi.org/10.1109/TNS.1977.4329098
Abstract
A simple, and rich in information, method for Q-measurement is developed. The method is essentially Fourier analysis, using a transient recorder and minicomputers. The word "simple" is for electronic circuit, though the program of computer is not so complicated. We use the revolution frequency of bunched protons as a "clock", so our method is free from recalibration or elimination of revolution frequency. We were able to measure Q-value even in the case that betatron oscillation was very rapidly damped.Keywords