Liquid−Liquid Extraction in the 96-Well Plate Format with SRM LC/MS Quantitative Determination of Methotrexate and Its Major Metabolite in Human Plasma
- 15 May 1999
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 71 (13) , 2340-2345
- https://doi.org/10.1021/ac981294y
Abstract
A method involving the semirobotic liquid−liquid extraction (LLE) in deep-well 96-well plates was developed for the quantitation of the anti-cancer/antiinflammatory drug methotrexate (MTX) and its major metabolite, 7-hydroxymethotrexate (7OH-MTX) in human plasma. The extraction time for the sample preparation was relatively short with four 96-well plates (384 samples) prepared in approximately 90 min by one person. The sample extracts were each analyzed within 1.2 min using a positive ion turbo-ionspray selected reaction monitoring liquid chromatography/mass spectrometric (SRM LC/MS) method in which 768 samples were easily analyzed within 22 h (maximum of 820 samples in 24 h). Deuterated internal standards, MTX-d3 and 7OH-MTX-d3, were used. The calibration curves for MTX and 7OH-MTX were linear (R2 > 0.997) and ranged from 0.5 to 250 and 0.75 to 100 ng/mL, respectively. The limit of quantitation (LOQ) for MTX and 7OH-MTX was 0.5 and 0.75 ng/mL, respectively; persistent carryover from the autosampler limited the LOQ achievable. The limit of detection (LOD) was 0.05 ng/mL for MTX and 0.1 ng/mL for 7OH-MTX. The intra- and inter-assay precision and accuracy did not exceed 15% for both MTX and 7OH-MTX. The recoveries were 61% for MTX and 47% for 7OH-MTX. The method was validated and demonstrated to be robust with high precision and accuracy.Keywords
This publication has 19 references indexed in Scilit:
- Peer Reviewed: Sample Preparation for LC/MS/MS: Analyzing Biological and Environmental SamplesAnalytical Chemistry, 1998
- Determination of methotrexate and its main metabolite 7-hydroxymethotrexate in human urine by high-performance liquid chromatography with normal solid-phase extractionJournal of Chromatography B: Biomedical Sciences and Applications, 1997
- Peer Reviewed: A Practical Guide to Analytical Method ValidationAnalytical Chemistry, 1996
- Determination of methotrexate and 7-hydroxymethotrexate by liquid chromatography for routine monitoring of plasma levelsJournal of Chromatography B: Biomedical Sciences and Applications, 1995
- Simultaneous quantitation of methotrexate and its two main metabolites in biological fluids by a novel solid-phase extraction procedure using high-performance liquid chromatographyJournal of Chromatography B: Biomedical Sciences and Applications, 1995
- Liquid chromatographic determination of the macrolide antibiotics roxithromycin and clarithromycin in plasma by automated solid-phase extraction and electrochemical detectionJournal of Chromatography A, 1995
- Sensitive determination of methotrexate in monkey plasma by high-performance liquid chromatography using on-line solid-phase extractionJournal of Chromatography B: Biomedical Sciences and Applications, 1994
- High-performance liquid chromatographic determination of methotrexate, 7-hydroxymethotrexate, 5-methyltetrahydrofolic acid and folinic acid in serum and cerebrospinal fluidJournal of Chromatography B: Biomedical Sciences and Applications, 1994
- Chromatographic analysis of anticancer drugsJournal of Chromatography B: Biomedical Sciences and Applications, 1990
- Drug Level Monitoring: CytostaticsJournal of Chromatography B: Biomedical Sciences and Applications, 1985