Electromyogenic Artifacts and Electroencephalographic Inferences
- 12 February 2009
- journal article
- review article
- Published by Springer Nature in Brain Topography
- Vol. 22 (1) , 7-12
- https://doi.org/10.1007/s10548-009-0079-4
Abstract
Muscle or electromyogenic (EMG) artifact poses a serious risk to inferential validity for any electroencephalography (EEG) investigation in the frequency-domain owing to its high amplitude, broad spectrum, and sensitivity to psychological processes of interest. Even weak EMG is detectable across the scalp in frequencies as low as the alpha band. Given these hazards, there is substantial interest in developing EMG correction tools. Unfortunately, most published techniques are subjected to only modest validation attempts, rendering their utility questionable. We review recent work by our laboratory quantitatively investigating the validity of two popular EMG correction techniques, one using the general linear model (GLM), the other using temporal independent component analysis (ICA). We show that intra-individual GLM-based methods represent a sensitive and specific tool for correcting on-going or induced, but not evoked (phase-locked) or source-localized, spectral changes. Preliminary work with ICA shows that it may not represent a panacea for EMG contamination, although further scrutiny is strongly warranted. We conclude by describing emerging methodological trends in this area that are likely to have substantial benefits for basic and applied EEG research.Keywords
This publication has 19 references indexed in Scilit:
- Validation of regression‐based myogenic correction techniques for scalp and source‐localized EEGPsychophysiology, 2009
- Enhanced automatic artifact detection based on independent component analysis and Renyi’s entropyNeural Networks, 2008
- A comparative study of different artefact removal algorithms for EEG signals acquired during functional MRINeuroImage, 2007
- Removal of EEG Noise and Artifact Using Blind Source SeparationJournal Of Clinical Neurophysiology, 2007
- Functional source separation applied to induced visual gamma activityHuman Brain Mapping, 2007
- EMG and EOG artifacts in brain computer interface systems: A surveyClinical Neurophysiology, 2007
- Estimating the number of independent components for functional magnetic resonance imaging dataHuman Brain Mapping, 2007
- Enhanced detection of artifacts in EEG data using higher-order statistics and independent component analysisNeuroImage, 2007
- Unified SPM–ICA for fMRI analysisNeuroImage, 2005
- EMG contamination of EEG: spectral and topographical characteristicsClinical Neurophysiology, 2003