Comparison of arterial and venous pH, bicarbonate, PCO2 and PO2 in initial emergency department assessment
- 1 August 2007
- journal article
- research article
- Published by BMJ in Emergency Medicine Journal
- Vol. 24 (8) , 569-571
- https://doi.org/10.1136/emj.2007.046979
Abstract
To determine the agreement between arterial and venous samples in a pathologically diverse patient population presenting at an emergency department (ED) with a view to obviating the need for arterial blood gas (ABG) analysis in initial ED evaluation. Prospective study of 95 patients (69 males, 26 females, mean (SD) age 52 (1.6) years) with diverse medical conditions, presenting at a tertiary health centre ED and deemed by the treating physician to require an ABG analysis. Arterial and venous samples for gas analysis were taken as close in time to each other as possible. The data thus obtained were analysed for agreement between pH, Pco(2), Po(2) and bicarbonate using the Bland-Altman method. The arterial and venous values of pH, bicarbonate and Pco(2) show acceptably narrow 95% limits of agreement using the Bland-Altman method (0.13 to -0.1, 4.3 to -5.8 and 6.8 to -7.6, respectively). Agreement in Po(2) measurements was poor (95% limits of agreement 145.3 to -32.9). Venous blood gas analysis for pH, bicarbonate and Pco(2) may be a reliable substitute for ABG analysis in the initial evaluation of an adult patient population presenting to the ED.Keywords
This publication has 9 references indexed in Scilit:
- Agreement between arterial and central venous values for pH, bicarbonate, base excess, and lactateEmergency Medicine Journal, 2006
- Correlation of Central Venous and Arterial Blood Gas Measurements in Mechanically Ventilated Trauma PatientsArchives of Surgery, 2005
- Agreement between bicarbonate measured on arterial and venous blood gasesEmergency Medicine, 2004
- Arterial Blood Gas Results Rarely Influence Emergency Physician Management of Patients with Suspected Diabetic KetoacidosisAcademic Emergency Medicine, 2003
- Prediction of arterial blood gas values from venous blood gas values in patients with acute respiratory failure receiving mechanical ventilation.2003
- Venous pCO2 and pH can be used to screen for significant hypercarbia in emergency patients with acute respiratory diseaseThe Journal of Emergency Medicine, 2002
- Venous pH can safely replace arterial pH in the initial evaluation of patients in the emergency departmentEmergency Medicine Journal, 2001
- Comparison of Blood Gas and Acid-Base Measurements in Arterial and Venous Blood Samples in Patients with Uremic Acidosis and Diabetic Ketoacidosis in the Emergency RoomAmerican Journal of Nephrology, 2000
- Reflex Sympathetic Dystrophy Following Arterial Blood Gas Sampling in the Intensive Care SettingChest, 1995