Abstract
Objective: Aims of the study were to develop an endoscopic technique to perform robot assisted coronary anastomoses, using a computer enhanced telemanipulator and to compare the quality of the anastomoses with those performed using a standard open technique. Methods: A surgical telemanipulator with two instrument arms and a central videoscopic arm was used to perform remote endoscopic coronary artery bypass grafting on isolated porcine hearts. The end effectors and the videoscope were placed through three 10 mm port incisions. All anastomoses (Cx to LAD) were performed using a double armed 7–0 Prolene suture of 5 or 7 cm in length. All operations were performed remotely from the master console using ten times magnification, tremor filtering and 3:1 motion scaling. Initially 20 anastomoses were performed to develop and train the technique. Then, 20 robot-assisted anastomoses (group I) were compared with 20 anastomoses using a standard open parachute technique (group II). All anastomoses were checked for patency and leakage. Patency was confirmed by bench angiography. After fixation, all anastomoses were macroscopically evaluated for patency, intactness, alignment, intimal tears and dehiscence. Both angiographic and pathologic evaluations were performed with the examiners blinded to the technique of anastomosis. Results: In the initial feasibility series, time for anastomosis was 18.2±9.1 min. All anastomoses were patent although minor stenoses were found in two and minor leakage was noted in five anastomoses. In the second series all anastomoses were patent, not leaking and showed a good run-off at angiography. Mean time for anastomosis in group I was 12.8±2.4 min as compared with 6.3±0.2 min in group II (PConclusion: Using the Intuitive surgical telemanipulator, it is possible to remotely perform endoscopic coronary anastomoses with the same quality as with an open standard technique after a brief learning curve. This will enable true endoscopic coronary artery bypass grafting with a precision that has not been achieved with any other previously applied endoscopic technique.Keywords
This publication has 9 references indexed in Scilit:
- Comparative study of two-dimensional and three-dimensional vision systems for minimally invasive surgerySurgical Endoscopy, 1998
- Use of an Intuitive Telemanipulator System for Remote Trauma Surgery: An Experimental StudyJournal of the American College of Surgeons, 1998
- Randomised study of influence of two-dimensional versus three-dimensional imaging on performance of laparoscopic cholecystectomyThe Lancet, 1998
- Robotic Surgical Instruments for Dexterity Enhancement in Thoracoscopic Coronary Artery Bypass GraftJournal of Laparoendoscopic & Advanced Surgical Techniques, 1997
- Minimally invasive thoracoscopically assisted coronary artery bypass surgeryEuropean Journal of Cardio-Thoracic Surgery, 1997
- Port-access coronary artery bypass grafting: A proposed surgical methodThe Journal of Thoracic and Cardiovascular Surgery, 1996
- Vascular applications of telepresence surgery: Initial feasibility studies in swineJournal of Vascular Surgery, 1996
- Unsolved problems in endoscopic surgerySurgical Endoscopy, 1993
- Development of a Surgical Robot for Cementless Total Hip ArthroplastyClinical Orthopaedics and Related Research, 1992