Accuracy and repeatability of left ventricular systolic and diastolic function measurements using an ambulatory radionuclide monitor
- 1 September 1992
- journal article
- research article
- Published by Springer Nature in European Journal of Nuclear Medicine and Molecular Imaging
- Vol. 19 (9) , 800-806
- https://doi.org/10.1007/bf00182823
Abstract
The accuracy and repeatability of a new ambulatory radionuclide detector (VEST) for left ventricular systolic (ejection fraction) and diastolic (peak filling rate) measurements were assessed. Seventeen patients underwent equilibrium radionuclide angiography immediately before and immediately after a VEST study. The accuracy was evaluated at the beginning and at the end of the VEST studies. Limits of agreement for the ejection fraction were −1%: 2% at the beginning of the VEST study and −4% at the end. Limits of agreement for the peak filling rate were −0.6: 0.6 at the beginning of the VEST study and −0.7: 0.5 at the end. For both measurements the limits of agreement were well within the clinical range. Repeatability was evaluated in a second group of 11 patients who underwent VEST studies in 2 separate days. The coefficient of repeatability (twice the standard deviation of the differences between the 2 studies) was 13 for the ejection fraction and 0.4 for the peak filling rate. Thus, the VEST is an accurate and repeatable method to measure both the ejection fraction and peak filling rate.Keywords
This publication has 16 references indexed in Scilit:
- Silent left ventricular dysfunction during routine activity after thrombolytic Therapy for acute myocardial infarctionJournal of the American College of Cardiology, 1990
- Left ventricular hypertrophy and impaired diastolic filling in essential hypertension. Diastolic mechanisms for systolic dysfunction during exercise.Circulation, 1990
- Usefulness of ambulatory radionuclide monitoring of left ventricular function early after acute myocardial infarction for predicting residual myocardial ischemiaThe American Journal of Cardiology, 1988
- Cardiac response to daily activities and exercise in normal subjects assessed by an ambulatory ventricular function monitorThe American Journal of Cardiology, 1987
- Effects of intravenous verapamil administration on left ventricular diastolic function in systemic hypertensionThe American Journal of Cardiology, 1987
- Intact systolic left ventricular function in clinical congestive heart failureThe American Journal of Cardiology, 1985
- Failure of antihypertensive therapy with diuretic, beta-blocking and calcium channel-blocking drugs to consistently reverse left ventricular diastolic filling abnormalitiesThe American Journal of Cardiology, 1984
- An ambulatory ventricular function monitor: Validation and preliminary clinical resultsThe American Journal of Cardiology, 1983
- Effects of verapamil on left ventricular systolic function and diastolic filling in patients with hypertrophic cardiomyopathy.Circulation, 1981
- Impaired left ventricular diastolic filling in patients with coronary artery disease: assessment with radionuclide angiography.Circulation, 1981