The average intensities of electric fields induced into tissue can be calculated if the morphology and conductivities of the tissue are known, and such values provide one estimate of dosage for a given field exposure level. However, the microanatomical structures of living tissue, which include gap junctions, tight junctions, highly charged cell coats, and extracellular matrices, as well as complex cell shapes, precludes a detailed characterization of the field and current distribution near the cells which are actually responding to the electric fields. This suggests that a more useful electric field dose metric may be one based on an induced physical effect on the cells. Electric fields have at least three distinct physical effects on cells: the normal plasma membrane potential will be altered; the ionic currents and ion distributions at the extracellular surface will be modified; and mechanical forces will be imposed at the cell surface. Each of these effects can, in principle, be measured through the application of specific microelectrode techniques. Here, the feasibility of using various intracellular and extracellular recording methods to obtain dosimetric values, as well as the contribution these measurements could make to our understanding of electric field interactions with biological tissue, are discussed.Keywords
This publication has 52 references indexed in Scilit:
- Viewing molecules with scanning tunneling microscopy and atomic force microscopyThe FASEB Journal, 1990
- Effects of low extracellular Ca2+ on cytosolic free Ca2+, Na+, and pH of MDCK cellsAmerican Journal of Physiology-Cell Physiology, 1990
- From atoms to integrated circuit chips, blood cells, and bacteria with the atomic force microscopeJournal of Vacuum Science & Technology A, 1990
- Scanning probe microscopy: Current status and future trendsJournal of Vacuum Science & Technology A, 1990
- Patch clamp recordings from membranes which contain gap junction channelsBiophysical Journal, 1989
- Dye and electrical coupling of endothelial cells in situTissue and Cell, 1989
- Ceramic Electrodes for ELF Bioeffects StudiesIEEE Transactions on Biomedical Engineering, 1984
- Dielectric enhancement and electrophoresis due to an electrochemical double layer: A uniform approximationThe Journal of Chemical Physics, 1984
- Anisotropy in the dielectric properties of skeletal muscleMedical & Biological Engineering & Computing, 1983
- New microelectrode techniques for intracellular work in small cellsNeuroscience, 1977