Abstract
High‐resolution magnetic resonance angiography is already a useful tool for studying mouse models of human disease. Magnetic resonance angiography in the mouse is typically performed using time‐of‐flight contrast. In this work, a new long‐circulating blood‐pool contrast agent—a liposomal nanoparticle with surface‐conjugated gadolinium (SC‐Gd liposomes)—was evaluated for use in mouse neurovascular magnetic resonance angiography. A total of 12 mice were imaged. Scan parameters were optimized for both time‐of‐flight and SC‐Gd contrast. Compared to time‐of‐flight contrast, SC‐Gd liposomes (0.08 mmol/kg) enabled improved small‐vessel contrast‐to‐noise ratio, larger field of view, shorter scan time, and imaging of venous structures. For a limited field of view, time‐of‐flight and SC‐Gd were not significantly different; however, SC‐Gd provided better contrast‐to‐noise ratio when the field of view encompassed the whole brain (P < 0.001) or the whole neurovascular axis (P < 0.001). SC‐Gd allowed acquisition of high‐resolution magnetic resonance angiography (52 × 52 × 100 micrometer3 or 0.27 nL), with 123% higher (P < 0.001) contrast‐to‐noise ratio in comparable scan time (∼45 min). Alternatively, SC‐Gd liposomes could be used to acquire high‐resolution magnetic resonance angiography (0.27 nL) with 32% higher contrast‐to‐noise ratio (P < 0.001) in 75% shorter scan time (12 min). Magn Reson Med, 2009.Keywords
Funding Information
- NIH/NCRR National Biomedical Technology Research Center (P41 RR005959)
- NCI Small Animal Imaging Resource Program (U24 CA092656)
- American Society of Neuroradiology
This publication has 27 references indexed in Scilit:
- Rapid production of specialized animal handling devices using computer-aided design and solid freeform fabricationJournal of Magnetic Resonance Imaging, 2009
- T1 Relaxivity of Core-encapsulated Gadolinium Liposomal Contrast Agents—Effect of Liposome Size and Internal Gadolinium ConcentrationAcademic Radiology, 2008
- Four‐dimensional MR microscopy of the mouse heart using radial acquisition and liposomal gadolinium contrast agentMagnetic Resonance in Medicine, 2008
- Magnetic Resonance Angiography Visualization of Abnormal Tumor Vasculature in Genetically Engineered MiceCancer Research, 2005
- Thrombosis of the Cerebral Veins and SinusesNew England Journal of Medicine, 2005
- High-resolution three-dimensional MR angiography of rodent tumors: Morphologic characterization of intratumoral vasculatureJournal of Magnetic Resonance Imaging, 2003
- Mouse Model of Cerebral AneurysmStroke, 2002
- Sliding interleaved KY (SLINKY) acquisition: A novel 3D MRA technique with suppressed slab boundary artifactJournal of Magnetic Resonance Imaging, 1998
- MR angiography with an ultrasmall superparamagnetic iron oxide blood pool agentJournal of Magnetic Resonance Imaging, 1997
- Three dimensional magnetic resonance microangiography of rat neurovasculatureMagnetic Resonance in Medicine, 1994