Optimization and Calibration of Laser Ablation–Inductively Coupled Plasma Atomic Emission Spectrometry by Measuring Vertical Spatial Intensity Profiles
- 1 January 1997
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 12 (2) , 177-182
- https://doi.org/10.1039/a606059e
Abstract
Vertical spatial emission intensity profiles for ICP-AES were measured to optimize and calibrate laser ablation sampling. Laser ablation sampling and laser ablation plus liquid nebulization sampling were studied. The position of maximum ICP emission intensity above the rf load coil changes with gas flow rate for both cases, with the maximum position shifting to higher regions in the plasma at higher flow rates. The maximum emission intensity occurs at a flow rate of approximately 0.2–0.3 l min -1 and at approximately 5–10 mm above the load coil, which are significantly different to the values normally employed for liquid nebulization. In addition, by measuring the spatial emission profiles for laser ablation and nebulization sampling, solutions can be used as standards to calibrate the composition of the laser ablated mass. Calibrated Zn:Cu ratios were measured using UV nanosecond and picosecond laser pulses. Stoichiometric laser ablation sampling of a brass alloy was achieved only by using UV picosecond laser pulses at high power density.Keywords
This publication has 38 references indexed in Scilit:
- Use of signal-to-root background ratio as the optimization parameter for inductively coupled plasma atomic emission spectroscopy with charged-coupled device detectionJournal of Analytical Atomic Spectrometry, 1996
- Optimised simultaneous multi-element analysis of environmental slurry samples by inductively coupled plasma atomic emission spectrometry using a segmented array charge-coupled device detectorAnalytica Chimica Acta, 1995
- Improved Design and Optimization of an Electrothermal Vaporization System for Inductively Coupled Plasma Atomic Emission SpectrometryMicrochemical Journal, 1995
- Automated simplex optimization for monochromatic imaging inductively coupled plasma atomic emission spectroscopySpectrochimica Acta Part B: Atomic Spectroscopy, 1995
- Optimization and use of flow injection vapour generation inductively coupled plasma mass spectrometry for the determination of arsenic, antimony and mercury in water and sea-water at ultratrace levelsJournal of Analytical Atomic Spectrometry, 1993
- Optimization of electrothermal vaporization of impurity elements in ceramic powders using inductively coupled plasma atomic emission spectroscopySpectrochimica Acta Part B: Atomic Spectroscopy, 1993
- Automatic multi-sample simultaneous multi-element analysis with a h.f. plasma torch and direct reading spectrometerAnalytica Chimica Acta, 1975
- Inductively coupled plasma-optical emission analytical spectrometryAnalytical Chemistry, 1974
- Studies of flame and plasma torch emission for simultaneous multi-element analysis—I: Preliminary investigationsSpectrochimica Acta Part B: Atomic Spectroscopy, 1972
- Emission-spectrometric detection of the elements at the nanogram per milliliter level using induction-coupled plasma excitationAnalytical Chemistry, 1969