Development of a Platinized and Ferrocene-Mediated Cholesterol Amperometric Biosensor Based on Electropolymerization of Polypyrrole in a Flow System
- 17 May 2002
- journal article
- Published by Springer Nature in Analytical Sciences
- Vol. 18 (5) , 537-542
- https://doi.org/10.2116/analsci.18.537
Abstract
The preparation of a cholesterol amperometric biosensor using a platinized Pt electrode as a support for the electropolymerization of a polypyrrole film, in which cholesterol oxidase and ferrocene monocarboxylic acid (electron-transfer mediator) were co-entrapped, is described. All the biosensor preparation steps (platinization and electropolymerization) and the cholesterol determination take place in the same flow system. The presence of the mediator enhances the sensitivity and selectivity of the platinized biosensor without modifying the dynamic parameters of the response, and the platinized layer improves the operational lifetime of the mediated sensor. The sensitivity obtained was 88.51 nA mM(-1) and the limit of detection was 12.4 microM of cholesterol. The analytical properties of the biosensor for the flow-injection determination of cholesterol were studied and compared with those of other more simple amperometric biosensor configurations.Keywords
This publication has 23 references indexed in Scilit:
- Criterion for Hill equation validity for description of biosensor calibration curvesAnalytica Chimica Acta, 2000
- Glucose biosensor based on glucose oxidase immobilized in electropolymerized polypyrrole and poly(o-phenylenediamine) films on a Prussian Blue-modified electrodeSensors and Actuators B: Chemical, 2000
- In situ preparation of overoxidized PPy/oPPD bilayer biosensors for the determination of glucose and cholesterol in serumSensors and Actuators B: Chemical, 1999
- In situ preparation of a cholesterol biosensor: entrapment of cholesterol oxidase in an overoxidized polypyrrole film electrodeposited in a flow system: Determination of total cholesterol in serumAnalytica Chimica Acta, 1999
- A glucose amperometric sensor based on covalent immobilization of glucose oxidase in poly‐2‐aminoaniline film via chloranil on platinized platinum electrodeElectroanalysis, 1997
- Platinization of Shapable Electroconductive Polymer Film for an Improved Glucose SensorJournal of the Electrochemical Society, 1996
- Flow injection analysis as a tool for studying polymer modified electrodesAnalytica Chimica Acta, 1996
- A Glucose Biosensor Based on Immobilization of Glucose Oxidase in Electropolymerized o-Aminophenol Film on Platinized Glassy Carbon ElectrodeAnalytical Chemistry, 1996
- Improvement of the analytical characteristics of an enzyme electrode for free and total cholesterol via laponite clay additivesAnalytica Chimica Acta, 1995
- Correlation between Permselectivity and Chemical Structure of Overoxidized Polypyrrole Membranes Used in Electroproduced Enzyme BiosensorsAnalytical Chemistry, 1995