Association of endovascular therapy of very small ruptured aneurysms with higher rates of procedure-related rupture
- 1 June 2008
- journal article
- Published by Journal of Neurosurgery Publishing Group (JNSPG) in Journal of Neurosurgery
- Vol. 108 (6) , 1088-1092
- https://doi.org/10.3171/jns/2008/108/6/1088
Abstract
Procedure-related rupture during endovascular therapy of intracranial aneurysms is associated with a mortality rate of more than one third. Previously ruptured aneurysms are a known risk factor for procedure-related rupture. The objective of this study was to evaluate whether very small, ruptured aneurysms are associated with more frequent intraprocedural ruptures. This was a retrospective cohort study in which the investigators examined consecutive ruptured aneurysms treated with coil embolization at a single institution. The study was approved by the institutional review board. Very small aneurysms were defined as < or = 3 mm. Procedure-related rupture was defined as contrast extravasation during treatment. Univariate analysis with the Fisher exact test and the Mann-Whitney U test was performed. Between August 1992 and January 2007, 682 aneurysms were selectively treated with coils in 668 patients. Procedure-related rupture occurred in 7 (11.7%) of 60 aneurysms < or = 3 mm, compared with 14 (2.3%) of 622 aneurysms > 3 mm (relative risk 5.2, 95% confidence interval 2.2-12.8; p < 0.001). Among cases with procedure-related rupture, inflation of a compliant balloon was associated with better outcome (Glasgow Outcome Scale Score > or = 4) compared with patients treated without balloon assistance (5 of 5 compared with 7 of 16; p = 0.05). Death resulting from procedure-related rupture occurred in 8 (38%) of 21 patients, and a vegetative state occurred in 1 patient. Clinical outcome was good in the other 12 patients (57%). Endovascular coil embolization of very small (< or = 3 mm) ruptured cerebral aneurysms is 5 times more likely to result in procedure-related rupture compared with larger aneurysms. Balloon inflation for hemostasis may be associated with better outcome in the event of intraprocedural rupture and merits further study.Keywords
This publication has 12 references indexed in Scilit:
- Validation of an Acute Ischemic Stroke ModelStroke, 2007
- Endovascular surgery for very small ruptured intracranial aneurysmsJournal of Neurosurgery, 2006
- International Subarachnoid Aneurysm Trial (ISAT) of neurosurgical clipping versus endovascular coiling in 2143 patients with ruptured intracranial aneurysms: a randomised trialThe Lancet, 2002
- Intraoperative complications in aneurysm surgery: a prospective national studyJournal of Neurosurgery, 2002
- Rupture of intracranial aneurysms during treatment with Guglielmi detachable coils: incidence, outcome, and risk factorsJournal of Neurosurgery, 2001
- Ruptured Intracranial Aneurysms: Acute Endovascular Treatment with Electrolytically Detachable Coils—A Prospective Randomized StudyRadiology, 1999
- Causes and management of aneurysmal hemorrhage occurring during embolization with Guglielmi detachable coilsJournal of Neurosurgery, 1998
- Intracranial berry aneurysms: angiographic and clinical results after endovascular treatment.Radiology, 1998
- Guglielmi detachable coil embolization of acute intracranial aneurysm: perioperative anatomical and clinical outcome in 403 patientsJournal of Neurosurgery, 1997
- Intraoperative Aneurysmal Rupture: Incidence, Outcome, and Suggestions for Surgical ManagementNeurosurgery, 1986