Influence of Time of Sampling Onset on Parameters Used for Activation Time Determination in Computerized Intraoperative Mapping
- 1 December 1991
- journal article
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 14 (12) , 2187-2192
- https://doi.org/10.1111/j.1540-8159.1991.tb06488.x
Abstract
The purpose of this work is to determine the sensitivity of the estimated time of peaks and maximum slopes, commonly used in activation time computations, to the instant at which sampling is initiated. Based on complex and quickly changing waveforms, 471 monopolar (MP) and bipolar (BP) epicardial responses in man were selected. These were decimated from 10 kHz to simulate sampling at frequencies ranging from 200 Hz to 2,000 Hz. The peak and maximum absolute slope for BP and the minimum slope for MP were computed repeatedly starting at successive 100 μsec intervals extending throughout the sampling period and compared with these parameters computed from the waveform sampled at 10 kHz. Slopes were estimated using each of four different algorithms. The average greatest shift (ACS) due to variations in sampling onset ranged from 11.2 ± 3.5 (200 Hz) to 0.3 ± 0.2 msec (2,000 Hz). For bipolar algorithms, the peak performed better than the slope algorithms (ACS: 5,9 ± 3,3 to 0.3 ± 1.0 msec). For MP algorithms, 2 point linear, and 3 and 5 point Lagrange slope estimates performed similarly (ACS: 5.6 ± 3.3 to 0.3 ± 0.2 msec); a 5 point least square fit algorithm performed poorly. Sampling MP and BP electrograms below 500 and 400, respectively, often caused maximum shifts > 4 msec. Thus, the resolution of the peak and estimated slope is not limited to the sampling period, variations in initiation of sampling can cause significant outliers especially at low sampling rates, and MP electrograms should be sampled faster than BP electrograms for comparable accuracy.Keywords
This publication has 9 references indexed in Scilit:
- Bandwidth‐Induced Errors in Parameters Used for Automated Activation Time Determination During Computerized Intraoperative Cardiac Mapping: Theoretical LimitsPacing and Clinical Electrophysiology, 1991
- Experience with Kapton‐Based Bipolar Electrode Arrays Used During Computerized Intraoperative MappingJournal of Cardiovascular Electrophysiology, 1990
- Epicardial Mapping: How to Measure Local Activation?Pacing and Clinical Electrophysiology, 1990
- The Precision of Electrophysiological Mapping: Localizing Depolarization Wave Fronts from Digitized Extracellular Eleetrograms and the Role of Data Sampling RateJournal of Cardiovascular Electrophysiology, 1990
- An automatic activation detector for bipolar cardiac electrogramsPublished by Institute of Electrical and Electronics Engineers (IEEE) ,1988
- Simultaneous computer mapping to facilitate intraoperative localization of accessory pathways in patients with Wolff-Parkinson-White syndromeThe American Journal of Cardiology, 1985
- An Interactive Computer System for Guiding the Surgical Treatment of Life-Threatening Ventricular TachycardiasIEEE Transactions on Biomedical Engineering, 1984
- A computerized method for the rapid display of ventricular activation during the intraoperative study of arrhythmias.Circulation, 1979
- Total Excitation of the Isolated Human HeartCirculation, 1970