Home Humidifiers as a Potential Source of Exposure to Microbial Pathogens, Endotoxins, and Allergens
- 1 September 1995
- journal article
- Published by Hindawi Limited in Indoor Air
- Vol. 5 (3) , 171-178
- https://doi.org/10.1111/j.1600-0668.1995.t01-1-00003.x
Abstract
The propensity of various types of home humidifiers to support and disseminate microbial contaminants into indoor air was tested. Reservoir water and air discharged from humidifiers seeded in the laboratory or naturally contaminated in the home were analyzed by standard microbiological methods. Clinically insignificant as well as overt or potentially pathogenic microorganisms were found to colonize the reservoirs of all types of humidifiers, but only cool mist and ultrasonic units readily aerosolized bacteria and endotoxin. Only cool mist units emitted hydrophobic fungal spores. Cool mist units discharged the greatest number of water particles in the inhalabk size range (4–16 μm) while ultrasonic units were more likely to emit respirable-sized water particles (< 0.2–4 μm). Overt pathogens isolated from humidifiers in homes included Legionella and a pathogenic Acanthamoeba. Aerosolizing humidifiers should thus be avoided if frequent, thorough cleaning of the units is not practical.Keywords
This publication has 29 references indexed in Scilit:
- Environmental endotoxin measurement: The Kinetic Limulus Assay with Resistant-parallel-line EstimationEnvironmental Research, 1992
- Immunomodulation by Bacterial EndotoxinCritical Reviews in Microbiology, 1990
- Indoor particle concentrations associated with use of tap water in portable humidifiersEnvironmental Science & Technology, 1988
- Airborne endotoxins and humidifier diseaseClinical and Experimental Allergy, 1984
- Nosocomial Legionnaires' Disease Caused by Aerosolized Tap Water from Respiratory DevicesThe Journal of Infectious Diseases, 1982
- Preliminary report on the pathogenicity of Legionella pneumophila for freshwater and soil amoebae.Journal of Clinical Pathology, 1980
- Allergic alveolitis caused by home humidifiers. Unusual clinical features and electron microscopic findingsJAMA, 1977
- Chronic hypersensitivity lung disease with recurrent episodes of hypersensitivity pneumonitis due to a contaminated central humidifierClinical and Experimental Allergy, 1976
- Fungus aerosols arising from cold-mist vaporizersJournal of Allergy and Clinical Immunology, 1974
- Hypersensitivity pneumonitis due to contamination of home humidifierJournal of Allergy and Clinical Immunology, 1972