Implementation of a Real-Time Human Movement Classifier Using a Triaxial Accelerometer for Ambulatory Monitoring
Top Cited Papers
- 10 January 2006
- journal article
- clinical trial
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Information Technology in Biomedicine
- Vol. 10 (1) , 156-167
- https://doi.org/10.1109/titb.2005.856864
Abstract
The real-time monitoring of human movement can provide valuable information regarding an individual's degree of functional ability and general level of activity. This paper presents the implementation of a real-time classification system for the types of human movement associated with the data acquired from a single, waist-mounted triaxial accelerometer unit. The major advance proposed by the system is to perform the vast majority of signal processing onboard the wearable unit using embedded intelligence. In this way, the system distinguishes between periods of activity and rest, recognizes the postural orientation of the wearer, detects events such as walking and falls, and provides an estimation of metabolic energy expenditure. A laboratory-based trial involving six subjects was undertaken, with results indicating an overall accuracy of 90.8% across a series of 12 tasks (283 tests) involving a variety of movements related to normal daily activities. Distinction between activity and rest was performed without error; recognition of postural orientation was carried out with 94.1% accuracy, classification of walking was achieved with less certainty (83.3% accuracy), and detection of possible falls was made with 95.6% accuracy. Results demonstrate the feasibility of implementing an accelerometry-based, real-time movement classifier using embedded intelligenceKeywords
This publication has 21 references indexed in Scilit:
- Classification of basic daily movements using a triaxial accelerometerMedical & Biological Engineering & Computing, 2004
- A pilot study of long-term monitoring of human movements in the home using accelerometryJournal of Telemedicine and Telecare, 2004
- The frequency content of gaitPublished by Elsevier ,2004
- Wearable sensors and telerehabilitationIEEE Engineering in Medicine and Biology Magazine, 2003
- Determining activity using a triaxial accelerometerPublished by Institute of Electrical and Electronics Engineers (IEEE) ,2002
- Validity of accelerometry for the assessment of moderate intensity physical activity in the fieldMedicine & Science in Sports & Exercise, 2000
- Motion pattern and posture: Correctly assessed by calibrated accelerometersBehavior Research Methods, Instruments & Computers, 2000
- Assessment of posture and motion by multichannel piezoresistive accelerometer recordingsPsychophysiology, 1997
- A triaxial accelerometer and portable data processing unit for the assessment of daily physical activityIEEE Transactions on Biomedical Engineering, 1997
- Detection of static and dynamic activities using uniaxial accelerometersIEEE Transactions on Rehabilitation Engineering, 1996