Evaluation of Patients after Coronary Artery Bypass Surgery: CT Angiographic Assessment of Grafts and Coronary Arteries
- 1 December 2003
- journal article
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 229 (3) , 749-756
- https://doi.org/10.1148/radiol.2293020856
Abstract
To evaluate the accuracy of electrocardiography (ECG)-gated multi-detector row computed tomography (CT) in enabling the detection of obstruction of both bypass grafts and coronary arteries in symptomatic patients who have undergone coronary artery bypass grafting. ECG-gated contrast material-enhanced multi-detector row CT angiography was performed in 24 patients after bypass surgery. Two independent blinded observers evaluated all graft and coronary segments (> or =2.0-mm diameter) for occlusion and stenosis (50%-99% luminal reduction). Conventional angiography was regarded as the standard of reference. Descriptive parameters were calculated, and the results for arterial grafts, venous grafts, and coronary arteries, as well as for high and low heart rates, were compared by using a two-sided Fisher exact test. The following results were obtained by observers 1 and 2, respectively: Of the 60 venous graft segments, 60 (100%) and 57 (95.0%) were assessable, with an overall detection of all 17 occlusions (both observers) and three (50.0%) and five (83.3%) of six stenoses. Of 26 arterial graft segments, 19 (73.1%) and 15 (57.7%) were assessable. In the assessable segments, four of four (100%) and two of three (66.7%) stenoses and occlusions were detected, while one and two obstructions were located in nonassessable segments. Of 211 coronary segments, 146 (69.2%) and 140 (66.4%) were assessable, and detection of 50%-100% obstruction yielded a sensitivity of 89.9% (71 of 79) and 79.4% (54 of 68) and a specificity of 74.6% (50 of 67) and 72.2% (52 of 72) for each observer. Unlike the assessment of venous and arterial grafts, assessment of the coronary arteries with multi-detector row CT was significantly better in patients with low heart rates (P <.01). Multi-detector row CT allows noninvasive angiographic evaluation of both coronary arteries and bypass grafts in patients who have undergone bypass surgery. Multi-detector row CT is more effective in examining venous grafts compared with arterial grafts and diffusely diseased coronary arteries.Keywords
This publication has 18 references indexed in Scilit:
- Cardiac Imaging by Means of Electrocardiographically Gated Multisection Spiral CT: Initial ExperienceRadiology, 2000
- Accuracy of Spiral Computed Tomography for Identifying Arterial and Venous Coronary Graft PatencyThe American Journal of Cardiology, 1997
- Noninvasive, Three-Dimensional Visualization of Coronary Artery Bypass Grafts by Electron Beam TomographyThe American Journal of Cardiology, 1997
- Coronary bypass graft fate and patient outcome: Angiographic follow-up of 5,065 grafts related to survival and reoperation in 1,388 patients during 25 yearsJournal of the American College of Cardiology, 1996
- Recurrence of angina after coronary artery bypass surgery: Predictors and prognosis (CASS registry)Journal of the American College of Cardiology, 1995
- Spiral CT Evaluation of Coronary Artery Bypass Graft PatencyJournal of Computer Assisted Tomography, 1993
- Sensitivity and specificity of assessing coronary bypass graft patency with ultrafast computed tomography: Results of a multicenter studyJournal of the American College of Cardiology, 1988
- Prospective evaluation of ultrafast cardiac computed tomography for determination of coronary bypass graft patency.Circulation, 1987
- Cine computed tomographic evaluation of aortocoronary bypass graft patencyJournal of the American College of Cardiology, 1986
- A reporting system on patients evaluated for coronary artery disease. Report of the Ad Hoc Committee for Grading of Coronary Artery Disease, Council on Cardiovascular Surgery, American Heart AssociationCirculation, 1975