Hemodynamics in humans during conventional and experimental methods of cardiopulmonary resuscitation.
- 1 September 1988
- journal article
- research article
- Published by Wolters Kluwer Health in Circulation
- Vol. 78 (3) , 630-639
- https://doi.org/10.1161/01.cir.78.3.630
Abstract
High-fidelity hemodynamic recordings of aortic and right atrial pressures and the coronary perfusion gradient (the difference between aortic and atrial pressure) were made in nine patients during cardiopulmonary resuscitation (CPR). Findings during conventional manual CPR were compared with those during high-impulse CPR (rate, 120 cycles/min with a shorter compression:relaxation ratio) as well as during pneumatic vest CPR with and without simultaneous ventilation and abdominal binding. Aortic peak pressure during conventional CPR averaged 61 +/- 29 mm Hg but varied widely (range, 39-126 mm Hg) among patients. Although the magnitude of improvement was modest, the high-impulse method was the only technique tested that significantly elevated both aortic peak pressure and the coronary perfusion gradient during cardiac arrest. During conventional CPR, aortic pressure rose from 61 +/- 29 to 80 +/- 39 mm Hg during high-impulse CPR, and the gradient rose from 9 +/- 11 to 14 +/- 15 mm Hg, respectively; p less than 0.01. The pneumatic vest method significantly improved peak aortic pressure but not the coronary perfusion gradient. Simultaneous ventilation and chest compression created high end-expiratory pressure and lowered the coronary perfusion gradient. Abdominal binding had no significant hemodynamic effects. This evaluation of experimental resuscitation methods in humans shows that the high-impulse chest compression method augments aortic pressure over levels achieved during conventional CPR methods; however, the improvement in pressure is modest and may not be clinically important. Simultaneous ventilation as well as abdominal binding during CPR were associated with no benefit; in fact, simultaneous ventilation appears to adversely affect cardiac perfusion and, therefore, should not be used during clinical resuscitation.This publication has 18 references indexed in Scilit:
- Aortic and right atrial pressures during standard and simultaneous compression and ventilation cpr in human beingsAnnals of Emergency Medicine, 1986
- Artificial perfusion techniques during cardiac arrest: Questions of experimental focus versus clinical needAnnals of Emergency Medicine, 1985
- Mechanical “cough” cardiopulmonary resuscitation during cardiac arrest in dogsThe American Journal of Cardiology, 1985
- Interposed abdominal compression-CPR in human subjectsAnnals of Emergency Medicine, 1984
- Intrapulmonary epinephrine during prolonged cardiopulmonary resuscitation: Improved regional blood flow and resuscitation in dogsAnnals of Emergency Medicine, 1984
- Augmentation of carotid flow during cardiopulmonary resuscitation by ventilation at high airway pressure simultaneous with chest compressionThe American Journal of Cardiology, 1981
- SIMULTANEOUS CHEST COMPRESSION AND VENTILATION AT HIGH AIRWAY PRESSURE DURING CARDIOPULMONARY RESUSCITATIONThe Lancet, 1980
- Importance of Prolonged Compression during Cardiopulmonary Resuscitation in ManNew England Journal of Medicine, 1977