Rate Hysteresis Pacing: How Valuable Is It? A Comparison of the Stimulation Rates of 70 and 50 Beats per Minute and Rate Hysteresis in Patients with Sinus Node Disease
- 1 May 1984
- journal article
- research article
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 7 (3) , 332-340
- https://doi.org/10.1111/j.1540-8159.1984.tb04914.x
Abstract
The main disadvantages of VVI pacing are absence of acceleration of the heart rate and loss of atrial synchronization. The alternatives to AAI and DDD pacing are stimulation at a low rate or hysteresis in order to decrease pacing time and thus reduce AV asynchrony. Nine patients who suffered from sinus node disease and who had been given a multiprogrammable pacemaker were monitored at each of three stimulation rates: 70, 50, and 70 bpm with an inhibition rate of 50 bpm (hysteresis). The total pacing time was shortest (p less than 0.05) for the stimulation rate of 50 bpm as compared to 70 bpm and hysteresis. It was also shorter for the hysteresis mode than for the 70 bpm mode (p less than 0.05). Only for hysteresis pacing was there a significant reduction in the number of changes from conducted cardiac rhythm to pacemaker-induced rhythm. Most patients found the 50 bpm mode preferable. None favored the hysteresis mode. In patients with sinus node disease and intermittent bradycardia being permanently paced, the periods of AV-conducted rhythm may be lengthened by reducing the stimulation rate from 70 bpm, with or without hysteresis pacing, to 50 bpm. In paced patients with sinus node disease and symptoms due to AV asynchrony, it might be worth trying a decrease in the stimulation rate before resorting to other pacemaker systems.Keywords
This publication has 27 references indexed in Scilit:
- A comparison of the acute and long-term hemodynamic effects of ventricular inhibited and atrial synchronous ventricular inhibited pacing.Circulation, 1982
- Natural history of conduction tissue disease in paced patientsThe American Journal of Cardiology, 1982
- Relation between Arrhythmic Sensations, Cardiac Arrhythmias and Psychological ProfileActa Medica Scandinavica, 1981
- The Importance of Beta, the Type II Error and Sample Size in the Design and Interpretation of the Randomized Control TrialNew England Journal of Medicine, 1978
- Three cases of hypotension and syncope with ventricular pacing: Possible role of atrial reflexesThe American Journal of Cardiology, 1978
- The Automatic Rate Adjustment Pacemaker. The Possibilities of Rate HysteresisPacing and Clinical Electrophysiology, 1978
- Undesirable cardiac arrhythmias associated with rate hysteresis pacemakersThe American Journal of Cardiology, 1976
- Pacemaker-induced cardiovascular failure: Hemodynamic and angiographic observationsThe American Journal of Cardiology, 1974
- Ventriculo-atrial Conduction in ManCirculation, 1970
- Atrial contribution to cardiac output in complete heart blockThe American Journal of Cardiology, 1965