Abstract
Aims: We sought to develop techniques for visualizing cochlear blood flow in live mammalian subjects using fluorescence microendoscopy. Background: Inner ear microcirculation appears to be intimately involved in cochlear function. Blood velocity measurements suggest that intense sounds can alter cochlear blood flow. Disruption of cochlear blood flow may be a significant cause of hearing impairment, including sudden sensorineural hearing loss. However, inability to image cochlear blood flow in a nondestructive manner has limited investigation of the role of inner ear microcirculation in hearing function. Present techniques for imaging cochlear microcirculation using intravital light microscopy involve extensive perturbations to cochlear structure, precluding application in human patients. The few previous endoscopy studies of the cochlea have suffered from optical resolution insufficient for visualizing cochlear microvasculature. Fluorescence microendoscopy is an emerging minimally invasive imaging modality that provides micron-scale resolution in tissues inaccessible to light microscopy. In this article, we describe the use of fluorescence microendoscopy in live guinea pigs to image capillary blood flow and movements of individual red blood cells within the basal turn of the cochlea. Methods: We anesthetized eight adult guinea pigs and accessed the inner ear through the mastoid bulla. After intravenous injection of fluorescein dye, we made a limited cochleostomy and introduced a compound doublet gradient refractive index endoscope probe 1 mm in diameter into the inner ear. We then imaged cochlear blood flow within individual vessels in an epifluorescence configuration using one-photon fluorescence microendoscopy. Results: We observed single red blood cells passing through individual capillaries in several cochlear structures, including the round window membrane, spiral ligament, osseous spiral lamina, and basilar membrane. Blood flow velocities within inner ear capillaries varied widely, with observed speeds reaching up to approximately 500 μm/s. Conclusion: Fluorescence microendoscopy permits visualization of cochlear microcirculation with micron-scale optical resolution and determination of blood flow velocities through analysis of video sequences.Keywords
This publication has 69 references indexed in Scilit:
- In Vivo Multiphoton Microscopy of Deep Brain TissueJournal of Neurophysiology, 2004
- Multiphoton endoscopyOptics Letters, 2003
- In vivo Micromechanical Measurements of the Organ of Corti in the Basal Cochlear TurnAudiology and Neurotology, 2002
- Cochlear Blood Flow Measurement in Patients with Me´nie`re's Disease and Other Inner Ear DisordersActa Oto-Laryngologica, 2001
- Laser Doppler Measurement of Cochlear Blood Flow Changes During Conditioning Noise ExposureActa Oto-Laryngologica, 2001
- Cochlea Endoscopy in vivoPublished by S. Karger AG ,1997
- Relative Blood Velocity Measurement in Individual Microvessels Using the Self-Mixing Effect in a Fiber-Coupled Helium-Neon LaserMicrovascular Research, 1995
- Polarized-Light Intravital Microscopy for Study of Cochlear MicrocirculationMicrovascular Research, 1993
- The Laser Doppler: A Non-invasive Measure of Cochlear Blood FlowActa Oto-Laryngologica, 1984
- Evaluation of cross-circulation through circle of Willis using an ultrasonic Doppler technique. Part II. Comparison between blood flow velocity by ultrasonic Doppler flowmetry and cerebrovascular resistance.Stroke, 1981