LUNG SOUNDS IN PATIENTS WITH EMPHYSEMA
- 1 January 1981
- journal article
- research article
- Published by Elsevier
- Vol. 124 (1) , 45-49
- https://doi.org/10.1164/arrd.1981.124.1.45
Abstract
An index of breath sound intensity (Ib) and the transmission of white noise (Tn) was recorded over 4 lung regions between apex and base in 8 subjects with emphysema. Ib and Tn were recorded over the whole range of lung volume from residual volume to total lung capacity. Each value was expressed as a fraction of the value recorded over the apical region with the help of an analog divider. The ratio of Ib to Tn was computed to correct for differences in Ib due to differences in transmission of sound. The ratio of Ib to Tn was also expressed as a fraction of the value recorded over the apex. Ib and Tn had definite patterns in subjects with emphysema but varied considerably from breath to breath. Ib and Tn were more reproducible in normal subjects. Magnitude and the sequence of Ib, Tn and Ib/Tn were also different in subjects with emphysema and normal subjects. The ratio of Ib to Tn is an index of sound production in normal subjects and subjects with emphysema. Production and transmission of breath sounds vary from breath to breath in patients with emphysema. There are areas of both increased and decreased production and transmission of sound. If regional breath sound production (Ib/Tn) is related to regional ventilation in persons with emphysema as in normal subjects, these findings further suggest that regional ventilation varies from breath to breath and is also altered drastically from the normal pattern, leading to a severe ventilation and perfusion inequality so characteristic of emphysematous lungs.This publication has 8 references indexed in Scilit:
- DISTRIBUTION OF REGIONAL VENTILATION MEASURED BY BREATH SOUNDSPublished by Elsevier ,1978
- BREATH SOUNDS AND REGIONAL VENTILATIONPublished by Elsevier ,1977
- Regional distribution of inspired gas in the lung.Journal of Applied Physiology, 1966
- STUDIES OF REGIONAL VENTILATION AND PERFUSION IN PULMONARY EMPHYSEMA USING XENON133Published by Elsevier ,1963
- REGIONAL PULMONARY FUNCTION STUDIED WITH XENON133*Journal of Clinical Investigation, 1962
- Lung volume, alveolar ventilation and perfusion interrelationships in chronic pulmonary emphysemaJournal of Applied Physiology, 1960
- Mechanical Factors in Distribution of Pulmonary VentilationJournal of Applied Physiology, 1956
- THE ACOUSTICS OF THE BRONCHIAL BREATH SOUNDSArchives of internal medicine (1960), 1927