Femoro‐tibial cartilage metrics from coronal MR image data: Technique, test–retest reproducibility, and findings in osteoarthritis
Open Access
- 21 November 2003
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 50 (6) , 1229-1236
- https://doi.org/10.1002/mrm.10648
Abstract
MRI-based measures of cartilage morphology are being increasingly used as surrogate markers in osteoarthritis. In contrast to other knee joint surfaces, quantitative analysis of the femoral condyles from sagittal MRI suffers from limited precision. The objective, therefore, was to develop a technique for reproducible assessment of femoral cartilage morphology from coronal image data. Coronal MR images (3D T1-w FLASHwe) of the knee were obtained in 16 healthy volunteers and in 7 patients with severe osteoarthritis (OA, prior to knee arthroplasty), with repositioning between repeated scans. After segmentation the cartilage volume, thickness, and joint surface areas were quantified in the tibia and in an anatomically defined region of the femoral condyle. Immediate test-retest interscan precision errors (CV%) for femoral cartilage volume were 3.0% (SD = 26 μl) and 3.2% (29 μl) medially and laterally in volunteers, and 3.0% (34 μl) and 7.0% (37 μl) in OA patients. The estimated loss, from cross sectional data, in the patients in the medial femoral condyle (–61%/–4.4 SD) was higher than that in the medial tibia (–45%/–3.1 SD) and compared favorably with precision errors (ratio > 16:1). The technique proposed overcomes some of the problems associated with sagittal scans and thus shows high promise for reliable assessment of femoro-tibial cartilage loss in OA. Magn Reson Med 50:1229–1236, 2003.Keywords
This publication has 33 references indexed in Scilit:
- Feasibility of T and Z scores from magnetic resonance imaging data for quantification of cartilage loss in osteoarthritisArthritis & Rheumatism, 2003
- Tibial and femoral cartilage changes in knee osteoarthritisAnnals of the Rheumatic Diseases, 2001
- Comparison and reproducibility of fast and conventional spoiled gradient‐echo magnetic resonance sequences in the determination of knee cartilage volumeJournal of Orthopaedic Research, 2000
- Validation of high-resolution water-excitation magnetic resonance imaging for quantitative assessment of thin cartilage layersOsteoarthritis and Cartilage, 2000
- Meniscal subluxation: association with osteoarthritis and joint space narrowingOsteoarthritis and Cartilage, 1999
- Radiographic assessment of osteoarthritis: comparison between existing methodologiesOsteoarthritis and Cartilage, 1999
- Determination of knee joint cartilage thickness using three‐dimensional magnetic resonance chondro‐crassometry (3D MR‐CCM)Magnetic Resonance in Medicine, 1996
- Magnetic resonance chondro‐crassometry (MR CCM): A method for accurate determination of articular cartilace thickness?Magnetic Resonance in Medicine, 1996
- Special article the economic cost and social and psychological impact of musculoskeletal conditionsArthritis & Rheumatism, 1995
- Accurate assessment of precision errors: How to measure the reproducibility of bone densitometry techniquesOsteoporosis International, 1995