Abstract
As MR scanner hardware has improved, allowing for increased gradient strengths, we are able to generate higher b values for diffusion-weighted (DW) imaging. Our purpose was to evaluate the appearance of the normal brain on DW MR images as the diffusion gradient strength ("b value") is increased from 1,000 to 3,000 s/mm2. Three sets of echo planar images were acquired at 1.5 T in 25 normal subjects (mean age 61 years) using progressively increasing strengths of a diffusion-sensitizing gradient (corresponding to b values of 0, 1,000, and 3,000 s/mm2). All other imaging parameters remained constant. Qualitative assessments of trace images were performed by two neuroradiologists, supplemented by quantitative measures of MR signal and noise in eight different anatomic regions. As gradient strength increased from b = 1,000 to 3,000, both gray and white matter structures diminished in signal as expected based on their relative diffusion coefficients [calculated average apparent diffusion coefficient (ADC) values: gray matter = 8.5 x 10(-4) mm2/s, white matter = 7.5 x 10(-4) mm2/s]. The signal-to-noise ratios for the b = 1,000 images were approximately 2.2 times higher than for the b = 3,000 images (p < 0.0001). As the strength of the diffusion-sensitizing gradient increased, white matter became progressively hyperintense to gray matter. Relative to the thalamus, for example, the average MR signal intensity of white matter structures increased by an average of 27.5%, with the densely packed white matter tracts (e.g., middle cerebellar peduncle, tegmentum, and internal capsule) increasing the most. Brain DW images obtained at b = 3,000 appear significantly different from those obtained at b = 1,000, reflecting expected loss of signal from all areas of brain in proportion to their ADC values. Consequently, when all other imaging parameters are held constant, b = 3,000 DW images appear significantly noisier than b = 1,000 images, and white matter tracts are significantly more hyperintense than gray matter structures.Keywords
This publication has 24 references indexed in Scilit:
- Diffusion-weighted MR imaging in acute stroke: theoretic considerations and clinical applications.American Journal of Roentgenology, 1999
- Imaging of Acute Cerebral IschemiaRadiology, 1999
- Acute Cerebral Infarction: Quantification of Spin-Density and T2 Shine-through Phenomena on Diffusion-weighted MR ImagesRadiology, 1999
- Clinical Outcome in Ischemic Stroke Predicted by Early Diffusion-Weighted and Perfusion Magnetic Resonance Imaging: A Preliminary AnalysisJournal of Cerebral Blood Flow & Metabolism, 1996
- Acute human stroke studied by whole brain echo planar diffusion‐weighted magnetic resonance imagingAnnals of Neurology, 1995
- Reversible focal ischemic injury demonstrated by diffusion-weighted magnetic resonance imaging in rats.Stroke, 1992
- Diffusion/perfusion MR imaging of acute cerebral ischemiaMagnetic Resonance in Medicine, 1991
- MR Diffusion Imaging of the Human BrainJournal of Computer Assisted Tomography, 1990
- Early detection of regional cerebral ischemia in cats: Comparison of diffusion‐ and T2‐weighted MRI and spectroscopyMagnetic Resonance in Medicine, 1990
- Spin Diffusion Measurements: Spin Echoes in the Presence of a Time-Dependent Field GradientThe Journal of Chemical Physics, 1965