Continuous glucose monitoring and closed‐loop systems
Top Cited Papers
- 28 June 2005
- journal article
- review article
- Published by Wiley in Diabetic Medicine
- Vol. 23 (1) , 1-12
- https://doi.org/10.1111/j.1464-5491.2005.01672.x
Abstract
Background The last two decades have witnessed unprecedented technological progress in the development of continuous glucose sensors, resulting in the first generation of commercial glucose monitors. This has fuelled the development of prototypes of a closed‐loop system based on the combination of a continuous monitor, a control algorithm, and an insulin pump.Method A review of electromechanical closed‐loop approaches is presented. This is followed by a review of existing prototypes and associated glucose sensors. A literature review was undertaken from 1960 to 2004.Results Two main approaches exist. The extracorporeal s.c.–s.c. approach employs subcutaneous glucose monitoring and subcutaneous insulin delivery. The implantable i.v.–i.p. approach adopts intravenous sampling and intraperitoneal insulin delivery. Feasibility of both solutions has been demonstrated in small‐scale laboratory studies using either the classical proportional–integral–derivative controller or a model predictive controller. Performance in the home setting has yet to be demonstrated.Conclusions The glucose monitor remains the main limiting factor in the development of a commercially viable closed‐loop system, as presently available monitors fail to demonstrate satisfactory characteristics in terms of reliability and/or accuracy. Regulatory issues are the second limiting factor. Closed‐loop systems are likely to be used first by health‐care professionals in controlled environments such as intensive care units.Keywords
This publication has 77 references indexed in Scilit:
- First-phase insulin secretion: does it exist in real life? Considerations on shape and functionAmerican Journal of Physiology-Endocrinology and Metabolism, 2004
- Lack of accuracy of continuous glucose sensors in healthy, nondiabetic children: results of the Diabetes Research in Children Network (DirecNet) accuracy studyThe Journal of Pediatrics, 2004
- Improved metabolic control in diabetic adolescents using the continuous glucose monitoring system (CGMS)Diabetes & Metabolism, 2003
- Reproducibility of plasma insulin kinetics during intraperitoneal insulin treatment by programmable pumpsDiabetes & Metabolism, 2003
- Accuracy of the continuous glucose monitoring system in inpatient and outpatient conditionsDiabetes & Metabolism, 2003
- External and implantable insulin pumps: current place in the treatment of diabetesExperimental and Clinical Endocrinology & Diabetes, 2001
- Computer Simulation of Plasma Insulin and Glucose Dynamics After Subcutaneous Insulin InjectionDiabetes Care, 1989
- Normalization of glycemia in diabetics during meals with insulin and glucagon delivery by the artificial pancreasDiabetes, 1977
- Control of Blood Glucose in Diabetics using an Artificial Pancreas*Australian and New Zealand Journal of Medicine, 1977
- CONTINUOUS IN VIVO DETERMINATION OF BLOOD GLUCOSE IN HUMAN SUBJECTSAnnals of the New York Academy of Sciences, 1960