Application of surface biopassivated disposable poly(dimethylsiloxane)/glass chips to a heterogeneous competitive human serum immunoglobulin G immunoassay with incorporated internal standard
- 7 March 2002
- journal article
- research article
- Published by Wiley in Electrophoresis
- Vol. 23 (5) , 740-749
- https://doi.org/10.1002/1522-2683(200203)23:5<740::aid-elps740>3.0.co;2-7
Abstract
A microfluidic platform for a heterogeneous competitive immunoassay of human immunoglobulin G (IgG) employing Cy5‐human IgG as tracer and Cy3‐mouse IgG as internal standard was developed. The device consisted of microchannels made of poly(dimethylsiloxane) and glass which were patterned with antibodies against human IgG and mouse IgG. Electrokinetic sample transport was employed in order to exploit the small difference between the net mobilities of analyte and tracer, thereby achieving favorable conditions for the performance of the competitive immunoreaction. The overall quality of the disposable chip and performance of the immunoassay were controlled by monitoring the fluorescence of bound tracer and bound internal standard. Analyses with an insufficient internal standard response were discarded, and immunoassay data evaluation was based on the ratio of tracer and internal standard fluorescence. Using synthetic samples in the range from 0 to 80 νg/mL IgG and alkaline running conditions, a concentration‐dependent response with reproducible Cy5/Cy3 signal ratios (average relative standard deviation of 6.8%) was obtained. Chips stored with solution in the channels at 4°C over a two‐month period were found to perform like freshly prepared chips, whereas chips stored dry at –20°C and rehydrated prior to use could not be employed. The analysis of patient sera showed that the immunoassay platform behaved differently in the presence of serum‐based samples. Using the same conditions as for the synthetic samples, no concentration dependence was noted. With a large excess of tracer, however, an IgG concentration dependence was observed, permitting distinction of samples of patients with normal IgG serum levels (8–16 mg/mL) from those with elevated IgG concentrations (> 16 mg/mL).Keywords
This publication has 16 references indexed in Scilit:
- Surface Biopassivation of Replicated Poly(dimethylsiloxane) Microfluidic Channels and Application to Heterogeneous Immunoreaction with On-Chip Fluorescence DetectionAnalytical Chemistry, 2001
- Electrokinetically Driven Microfluidic Chips with Surface-Modified Chambers for Heterogeneous ImmunoassaysAnalytical Chemistry, 2001
- Microminiaturized immunoassays using quantum dots as fluorescent label by laser confocal scanning fluorescence detectionJournal of Immunological Methods, 2001
- Determination of Carcinoembryonic Antigen in Human Sera by Integrated Bead-Bed Immunoasay in a Microchip for Cancer DiagnosisAnalytical Chemistry, 2001
- Development and characterization of an ELISA assay in PDMS microfluidic channelsSensors and Actuators B: Chemical, 2001
- Micromosaic ImmunoassaysAnalytical Chemistry, 2000
- Chemiluminescence detection in integrated post‐separation reactors for microchip‐based capillary electrophoresis and affinity electrophoresisElectrophoresis, 1998
- Micellar Electrokinetic Chromatography Separations and Analyses of Biological Samples on a Cyclic Planar MicrostructureAnalytical Chemistry, 1996
- Microchip Electrophoretic Immunoassay for Serum CortisolAnalytical Chemistry, 1996
- The quantification of human IgG subclasses in reference preparationsClinica Chimica Acta; International Journal of Clinical Chemistry, 1985