Evaluation of poly(DTH carbonate), a tyrosine‐derived degradable polymer, for orthopedic applications
- 1 November 1995
- journal article
- research article
- Published by Wiley in Journal of Biomedical Materials Research
- Vol. 29 (11) , 1337-1348
- https://doi.org/10.1002/jbm.820291105
Abstract
The polymerization of desaminotyrosinetyrosylhexyl ester (DTH) with phosgene gives rise to poly(DTH carbonate), a new pseudopoly(amino acid). To evaluate the performance of this bioabsorbable material in orthopedic applications, the tissue responses elicited by compression‐molded pins of poly(DTH carbonate) and clinically used polydioxanone pins (PDS; Orthosorb®) were compared. The two types of pins were implanted in the paravertebral muscle and in the metaphyseal proximal tibia and distal femur of 10 White New Zealand Rabbits for 1, 2, 4, and 26 weeks. The tissue response was evaluated using histologic staining of softand hard‐tissue sections, fluorescent bone marker incorporation, and backscattered electron imaging. In soft tissue, both poly(DTH carbonate) and PDS elicited a mild inflammatory response resulting in encapsulation. During the disintegration phase, the PDS implants triggered a foreign body response involving the phagocytosis of polymeric debris by histiocytes and giant cells. No such response was observed for poly(DTH carbonate). In hard tissue, close bone apposition was observed throughout the 26‐week test period for poly(DTH carbonate) implants. At the 26‐week time point, the poly(DTH carbonate) implants exhibited surface erosion and were penetrated by new bone. In contrast, an intervening fibrous tissue layer was always present between the PDS pins and the bone. At 26 weeks, the PDS implants had partially resorbed and a foreign body response characterized by infiltration of inflammatory cells, and bone resorption was observed in several of the implantation sites. This study indicates that poly(DTH carbonate) and PDS exhibit fundamentally different interactions with hard tissue, and that poly(DTH carbonate) is a promising orthopedic implant material. © 1995 John Wiley & Sons, Inc.Keywords
This publication has 22 references indexed in Scilit:
- Evaluation of a series of tyrosine‐derived polycarbonates as degradable biomaterialsJournal of Biomedical Materials Research, 1994
- Examination of efferent lymph nodes after 2 years of transcortical implantation of poly(L‐lactide) containing plugs: A case reportJournal of Biomedical Materials Research, 1993
- Biological response of intramedullary bone to poly‐L‐lactic acidJournal of Applied Biomaterials, 1993
- Tyrosine‐derived polycarbonates: Backbone‐modified “pseudo”‐poly(amino acids) designed for biomedical applicationsBiopolymers, 1992
- Desaminotyrosyl—Tyrosine Alkyl EstersPublished by American Chemical Society (ACS) ,1991
- Physico-mechanical properties of degradable polymers used in medical applications: A comparative studyBiomaterials, 1991
- The influence of different degrees of stiffness of fixation plates on experimental bone healingJournal of Orthopaedic Research, 1988
- Preliminary report on the osteogenic potential of a biodegradable copolymer of polyactide (PLA) and polyglycolide (PGA)Journal of Biomedical Materials Research, 1983