Skin blood flow during incremental exercise in a thermoneutral and a hot dry environment
- 1 January 1987
- journal article
- research article
- Published by Springer Nature in European Journal of Applied Physiology
- Vol. 56 (3) , 273-280
- https://doi.org/10.1007/bf00690892
Abstract
Eight physically fit men performed two incremental bicycle ergometer tests, one in an ambient temperature of 25° C and the other at 40° C. Oesophageal temperature (Tes) increased continuously throughout the tests up to 38.0 and 38.3° C, respectively. In both enviroments, forearm blood flow (plethysmography) was linearly related to Tes above the Tes threshold for vasodilation, but at the heaviest work loads this relationship was clearly attenuated and therefore indicated skin vasoconstriction, which tended to be more pronounced at 25° C. During recovery at 25° C, in some subjects the forearm blood flow increased above the levels observed at the end of the graded exercise in spite of a decreasing Tes. Skin blood flow, measured by laser Doppler flow meter at the shoulder, was quantitatively different but, on average, seemed to reveal the same response pattern as the forearm blood flow. In spite of the higher level of skin blood flow in the heat, blood lactate accumulation did not differ between the two environments. The present results suggest that there is competition between skin vasoconstriction and vasodilation at heavy work rates, the former having precedence in a thermoneutral environment to increase muscle perfusion. During short-term graded exercise in a hot environment, skin vasoconstriction with other circulatory adjustments seems to be able to maintain adequate muscle perfusion at heavy work levels, but probably not during maximum exercise.Keywords
This publication has 34 references indexed in Scilit:
- Influence of heat stress and acclimation on maximal aerobic powerEuropean Journal of Applied Physiology, 1985
- Circulatory Adjustments to Exercise and Heat StressAnnual Review of Physiology, 1983
- Semi-Automatic Blood Lactate Assay: Experiences from an Exercise LaboratoryInternational Journal of Sports Medicine, 1983
- Plasma Catecholamines in Trained and Untrained Volunteers During Graduated Exercise*International Journal of Sports Medicine, 1981
- Evaluation of a Laser Doppler Flowmeter for Measurement of Tissue Blood FlowIEEE Transactions on Biomedical Engineering, 1980
- The Transition from Aerobic to Anaerobic MetabolismResearch Quarterly for Exercise and Sport, 1980
- Plasma catecholamine concentration during dynamic exercise involving different muscle groupsEuropean Journal of Applied Physiology, 1974
- Reductions in cardiac output, central blood volume, and stroke volume with thermal stress in normal men during exercise.Journal of Clinical Investigation, 1966
- The interrelation of thermoregulatory and baroreceptor reflexes in the control of the blood vessels in the human forearmThe Journal of Physiology, 1966
- The measurement of volume changes in human limbsThe Journal of Physiology, 1953