Band artifacts due to bulk motion
Open Access
- 3 December 2002
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 48 (6) , 1028-1036
- https://doi.org/10.1002/mrm.10314
Abstract
Band artifacts due to bulk motion were investigated in images acquired with fast gradient echo sequences. A simple analytical calculation shows that the width of the artifacts has a square‐root dependence on the velocity of the imaged object, the time taken to acquire each line of k‐space and the field of view in the phase‐encoding direction. The theory furthermore predicts that the artifact width can be reduced using parallel imaging by a factor equal to the square root of the acceleration parameter. The analysis and results are presented for motion in the phase‐ and frequency‐encoding directions and comparisons are made between sequential and centric ordering. The theory is validated in phantom experiments, in which bulk motion is simulated in a controlled and reproducible manner by rocking the scan table back and forth along the bore axis. Preliminary cardiac studies in healthy human volunteers show that dark bands may be observed in the endocardium in images acquired with nonsegmented fast gradient echo sequences. The fact that the position of the bands changes with the phase‐encoding direction suggests that they may be artifacts due to motion of the heart walls during the image acquisition period. Magn Reson Med 48:1028–1036, 2002.Keywords
This publication has 14 references indexed in Scilit:
- Optimization of view ordering for motion artifact suppressionMagnetic Resonance Imaging, 2001
- Magnetic resonance first-pass myocardial perfusion imaging: Clinical validation and future applicationsJournal of Magnetic Resonance Imaging, 1999
- SENSE: Sensitivity encoding for fast MRIMagnetic Resonance in Medicine, 1999
- Simultaneous acquisition of spatial harmonics (SMASH): Fast imaging with radiofrequency coil arraysMagnetic Resonance in Medicine, 1997
- Two-point interference method for suppression of ghost artifacts due to motionJournal of Magnetic Resonance Imaging, 1993
- K‐space description for MR imaging of dynamic objectsMagnetic Resonance in Medicine, 1993
- Motional phase artifacts in fourier transform MRIMagnetic Resonance in Medicine, 1989
- Acquisition order and motional artifact reduction in spin warp imagesMagnetic Resonance in Medicine, 1988
- Pseudo‐gating: Elimination of periodic motion artifacts in magnetic resonance imaging without gatingMagnetic Resonance in Medicine, 1987
- MR image artifacts from periodic motionMedical Physics, 1985