A CT‐based Monte Carlo simulation tool for dosimetry planning and analysis
- 1 January 1998
- journal article
- research article
- Published by Wiley in Medical Physics
- Vol. 25 (1) , 1-11
- https://doi.org/10.1118/1.598167
Abstract
The Los Alamos code MCNP4A (Monte Carlo N-Particle version 4A) is currently used to simulate a variety of problems ranging from nuclear reactor analysis to boron neutron capture therapy. A graphical user interface has been developed that automatically sets up the MCNP4A geometry and radiation source requirements for a three-dimensional Monte Carlo simulation using computed tomography data. The major drawback for this dosimetry system is the amount of time to obtain a statistically significant answer. A specialized patch file has been developed that optimizes photon particle transport and dose scoring within the standard MCNP4A lattice geometry. The transport modifications produce a performance increase (number of histories per minute) of approximately 4.7 based upon a 6 MV point source centered within a 30 x 30 x 30 cm(3) lattice water phantom and 1 x 1 x 1 mm(3) voxels. The dose scoring modifications produce a performance increase of approximately 470 based upon a tally section of greater than 1 x 10(4) lattice elements and a voxel size of 5 mm(3). Homogeneous and heterogeneous benchmark calculations produce good agreement with measurements using a standard water phantom and a high-and low-density heterogeneity phantom. The dose distribution from a typical mediastinum treatment planning setup is presented for qualitative analysis and comparison versus a conventional treatment planning system. (C) 1998 American Association of Physicists in Medicine.Keywords
This publication has 27 references indexed in Scilit:
- Monte Carlo-based treatment planning for boron neutron capture therapy using custom designed models automatically generated from CT dataInternational Journal of Radiation Oncology*Biology*Physics, 1996
- A verification of the Monte Carlo code MCNP for thick target bremsstrahlung calculationsMedical Physics, 1995
- Dosimetry of 6-MV x-ray beam penumbraMedical Physics, 1993
- X‐ray sources of medical linear accelerators: Focal and extra‐focal radiationMedical Physics, 1993
- Head-scatter factors and effective x-ray source positions in a 25-MV linear acceleratorMedical Physics, 1992
- Angular distribution of bremsstrahlung from 15‐MeV electrons incident on thick targets of Be, Al, and PbMedical Physics, 1991
- Differences in electron depth‐dose curves calculated with EGS and ETRAN and improved energy‐range relationshipsMedical Physics, 1986
- Impact of tumor control on survival in carcinoma of the lung treated with irradiationInternational Journal of Radiation Oncology*Biology*Physics, 1986
- On the relationship between computed tomography numbers and specific gravityPhysics in Medicine & Biology, 1981
- Epoxy resin based tissue substitutesThe British Journal of Radiology, 1977