Evaluation of computed tomography coronary angiography in patients with a high heart rate using 16-slice spiral computed tomography with 0.37-s gantry rotation time
- 11 March 2005
- journal article
- research article
- Published by Springer Nature in European Radiology
- Vol. 15 (6) , 1105-1109
- https://doi.org/10.1007/s00330-005-2714-0
Abstract
The aim of our study is to evaluate computed tomography (CT) coronary angiography in patients with a high heart rate using 16-slice spiral CT with 0.37-s gantry rotation time. We compare the image quality of patients whose heart rates were over 70 beats per minute (bpm) with that of patients whose heart rates were 70 bpm or less. Sixty patients with various heart rates underwent retrospectively ECG-gated multislice spiral CT (MSCT) coronary angiography. Two experienced observers who were blind to the heart rates of the patients evaluated all the MSCT coronary angiographic images and calculated the assessable segments. A total of 620 out of 891 (69.6%) segments were satisfactorily visualized. On average, 10.3 coronary artery segments per patient could be evaluated. In 36 patients whose heart rates were below 70 bpm [mean 62.2 bpm±5.32 (standard deviation, SD)], the number of assessable segments was 10.72±2.02 (SD). In the other 24 patients whose heart rates were above 70 bpm [mean 78.6 bpm±8.24 (SD)], the corresponding number was 9.75±1.74 (SD). No statistically significant difference was found in these two subgroups’ t test, P>0.05. The new generation of 16-slice spiral CT with 0.37-s rotation time can satisfactorily evaluate the coronary arteries of patients with high heart rates (above 70 bpm, up to 102 bpm).Keywords
This publication has 11 references indexed in Scilit:
- Coronary arteries: assessment of image quality and optimal reconstruction window in retrospective ECG-gated multislice CT at 375-ms gantry rotation timeEuropean Radiology, 2004
- Multislice CT imaging of anomalous coronary arteriesEuropean Radiology, 2004
- Detection, visualization and evaluation of anomalous coronary anatomy on 16-slice multidetector-row CTEuropean Radiology, 2004
- Non-invasive coronary angiography with multislice spiral computed tomography: impact of heart rateHeart, 2002
- Heart-rate-adapted image reconstruction in multidetector-row cardiac CT: influence of physiological and technical prerequisite on image qualityEuropean Radiology, 2002
- Non-invasive coronary angiography with high resolution multidetector-row computed tomography. Results in 102 patientsEuropean Heart Journal, 2002
- Reliable Noninvasive Coronary Angiography With Fast Submillimeter Multislice Spiral Computed TomographyCirculation, 2002
- Noninvasive Visualization of Coronary Arteries Using Contrast-Enhanced Multidetector CT: Influence of Heart Rate on Image Quality and Stenosis DetectionAmerican Journal of Roentgenology, 2002
- Influence of heart rate on vessel visibility in noninvasive coronary angiography using new multislice computed tomographyClinical Imaging, 2002
- Coronary Arteries: Retrospectively ECG-gated Multi–Detector Row CT Angiography with Selective Optimization of the Image Reconstruction WindowRadiology, 2001