Fixation, Polyethylene Wear, and Pelvic Osteolysis in Primary Total Hip Replacement
- 1 December 1999
- journal article
- research article
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 369 (369) , 157-164
- https://doi.org/10.1097/00003086-199912000-00016
Abstract
A multicenter retrospective review was performed analyzing 1081 primary total hip replacements in 944 patients using the Harris Galante-I cementless acetabular component with screw fixation. All patients were followed up for a minimum of 5 years with a mean followup of 81 months. Linear polyethylene wear averaged 0.11 mm/year (range, 0-0.86 mm/year). Pelvic osteolysis was seen in 25 patients (2.3%). Migration of the acetabular component was seen in four hips. A subgroup of patients was reanalyzed at a minimum followup of 10 years. The mean linear polyethylene wear rate remained 0.11 mm/year. In this group, only one socket had migrated. There was an association between wear rate and age. On average, younger patients had higher wear rates. The risk for having pelvic osteolysis develop and the need for revision surgery also was age-related. Twenty-two percent of hip replacements (15 hips) in patients younger than 50 years of age at the time of their index operation had pelvic osteolysis develop. In contrast, for patients older than 50 years of age at the time of surgery only 7.8% (eight hips) had osteolysis of the pelvis develop. For patients older than 70 years of age at the time of primary total hip replacement, none had pelvic osteolysis develop.Keywords
This publication has 19 references indexed in Scilit:
- Osteolysis after Charnley primary low-friction arthroplastyThe Journal of Bone and Joint Surgery. British volume, 1998
- Factors Affecting Aseptic Failure of Fixation after Primary Charnley Total Hip ArthroplastyJournal of Bone and Joint Surgery, 1997
- Treatment of Pelvic Osteolysis Associated with a Stable Acetabular Component Inserted without Cement as Part of a Total Hip Replacement*Journal of Bone and Joint Surgery, 1997
- In Vivo Skeletal Responses to Porous-Surfaced Implants Subjected to Small Induced Motions*Journal of Bone and Joint Surgery, 1997
- The Porous-Coated Anatomic Total Hip ProsthesisJournal of Bone and Joint Surgery, 1996
- Total hip replacement with insertion of an acetabular component without cement and a femoral component with cement. Four to seven-year results.Journal of Bone and Joint Surgery, 1995
- A quantitative in vitro assessment of fit and screw fixation on the stability of a cementless hemispherical acetabular componentThe Journal of Arthroplasty, 1994
- Histological and radiographic assessment of well functioning porous-coated acetabular components. A human postmortem retrieval study.Journal of Bone and Joint Surgery, 1993
- Histology of porous-coated acetabular components: 25 cementless cups retrieved after arthroplastyActa Orthopaedica, 1993
- The effect of improved cementing techniques on component loosening in total hip replacement. An 11-year radiographic reviewThe Journal of Bone and Joint Surgery. British volume, 1990