Liquid Chromatographic Determination of Multiple Sulfonamides, Nitrofurans, and Chloramphenicol Residues in Pasteurized Milk
Open Access
- 1 January 2002
- journal article
- research article
- Published by Oxford University Press (OUP) in Journal of AOAC INTERNATIONAL
- Vol. 85 (1) , 20-24
- https://doi.org/10.1093/jaoac/85.1.20
Abstract
A rapid and selective liquid chromatographic method was developed to detect 6 sulfonamides, 3 nitrofurans, and chloramphenicol residues in pasteurized milk. The 10 drugs were extracted with chloroform–acetone and the organic phase was evaporated; the residues were dissolved in an aqueous sodium acetate buffer solution 0.02M (pH = 4.8), and the fat was removed by washing with hexane. The aqueous layer was collected, filtered, and injected. The 6 sulfonamides and chloramphenicol were detected at 275 nm ultraviolet (UV) using a gradient system starting with sodium acetate buffer solution–acetonitrile (95 + 5) and finishing with sodium acetate buffer solution–acetonitrile (80 + 20). Nitrofurans were detected at 375 nm (UV) isocratically with sodium acetate buffer solution–acetonitrile (80 + 20). For 50 ppb fortified milk, the average recoveries were (sulfathiazole) 65.52%; (sulfamerazine) 75.36%; (sulfamethazine) 93.94%; (sulfachlorpyridazine) 75.94%; (sulfamethoxazole) 85.18%; (sulfamonomethoxine) 83.45%; (chloramphenicol) 104.17%; (nitrofurazone) 91.81%; (furazolidone) 100.76%; and (furaltadone) 72.38%. Method detection limits ranged from 4 ppb (nitrofurazone) to 16 ppb (sulfamethazine). Some matrix interferences (3–7 ppb) were observed only with sulfonamides.Keywords
This publication has 0 references indexed in Scilit: