Influence of Instrument Parameters on Nonspectroscopic Interferences in Inductively Coupled Plasma-Mass Spectrometry
- 1 July 1987
- journal article
- research article
- Published by SAGE Publications in Applied Spectroscopy
- Vol. 41 (5) , 897-903
- https://doi.org/10.1366/0003702874448193
Abstract
The effect of ion lens voltage settings and plasma conditions on nonspectroscopic interferences has been studied. The change in ion count rate for 7Li, 10B, 45Sc, and 89Y in the presence of Na, K, Sr, and Cs under a variety of experimental conditions is reported. The ion lens voltage setting did not affect the degree of nonspectroscopic interferences with the use of the Einzel ion optic system. Suppression effects were increased when the power was increased and the sampling depth decreased. Changes in nebulizer pressure resulted in interference trends, which varied with the concomitant element being studied. Sodium caused a decrease in interference effects with increasing nebulizer pressure, whereas Cs caused an increase under the same experimental conditions. Suppression of analyte ion count rate increased with increasing sample solution uptake rate and increasing atomic mass of concomitant elements.Keywords
This publication has 15 references indexed in Scilit:
- Determination of lead isotope ratios by inductively coupled plasma-mass spectrometry (ICP-MS)Spectrochimica Acta Part B: Atomic Spectroscopy, 1987
- Oxide, Hydroxide, and Doubly Charged Analyte Species in Inductively Coupled Plasma/Mass SpectrometryApplied Spectroscopy, 1986
- Background Spectral Features in Inductively Coupled Plasma/Mass SpectrometryApplied Spectroscopy, 1986
- Suppression of analyte signal by various concomitant salts in inductively coupled plasma mass spectrometryAnalytical Chemistry, 1986
- The effect of plasma operating parameters on analyte signals in inductively coupled plasma-mass spectrometrySpectrochimica Acta Part B: Atomic Spectroscopy, 1985
- Elemental analysis with an atmospheric pressure plasma (MIP, ICP)/quadrupole mass spectrometer systemSpectrochimica Acta Part B: Atomic Spectroscopy, 1983
- Inductively coupled plasma source mass spectrometry using continuum flow ion extractionThe Analyst, 1983
- Interference from easily ionizable element matrices in inductively coupled plasma emission spectrometry—a spatial studySpectrochimica Acta Part B: Atomic Spectroscopy, 1981
- Inductively coupled argon plasma as an ion source for mass spectrometric determination of trace elementsAnalytical Chemistry, 1980
- Mass-spectrometric analysis of solutions using an atmospheric pressure ion sourceThe Analyst, 1975