Dynamic measurements of CO diffusing capacity using discrete samples of alveolar gas
- 1 January 1983
- journal article
- research article
- Published by American Physiological Society in Journal of Applied Physiology
- Vol. 54 (1) , 73-79
- https://doi.org/10.1152/jappl.1983.54.1.73
Abstract
It has been shown that measurements of the diffusing capacity of the lung for CO made during a slow exhalation [DLCO(exhaled)] yield information about the distribution of the diffusing capacity in the lung that is not available from the commonly measured single-breath diffusing capacity [DLCO(SB)]. Current techniques of measuring DLCO(exhaled) require the use of a rapid-responding (less than 240 ms, 10–90%) CO meter to measure the CO concentration in the exhaled gas continuously during exhalation. DLCO(exhaled) is then calculated using two sample points in the CO signal. Because DLCO(exhaled) calculations are highly affected by small amounts of noise in the CO signal, filtering techniques have been used to reduce noise. However, these techniques reduce the response time of the system and may introduce other errors into the signal. We have developed an alternate technique in which DLCO(exhaled) can be calculated using the concentration of CO in large discrete samples of the exhaled gas, thus eliminating the requirement of a rapid response time in the CO analyzer. We show theoretically that this method is as accurate as other DLCO(exhaled) methods but is less affected by noise. These findings are verified in comparisons of the discrete-sample method of calculating DLCO(exhaled) to point-sample methods in normal subjects, patients with emphysema, and patients with asthma.This publication has 8 references indexed in Scilit:
- Improved accuracy and precision of single-breath CO diffusing capacity measurementsJournal of Applied Physiology, 1981
- Nonlinear increases in diffusing capacity during exercise by seated and supine subjectsJournal of Applied Physiology, 1981
- Comparison of lung diffusing capacity during rebreathing and during slow exhalationRespiration Physiology, 1981
- Effect of ventilation and diffusion nonuniformity on DLCO (exhaled) in a lung modelJournal of Applied Physiology, 1980
- Effect of static or slowly flowing blood on carbon monoxide diffusion in dog lungsJournal of Applied Physiology, 1979
- CLINICAL USEFULNESS OF A SCREENING-TEST TO DETECT STATIC PULMONARY BLOOD USING A MULTIPLE-BREATH ANALYSIS OF DIFFUSING-CAPACITYPublished by Elsevier ,1979
- Pulmonary diffusing capacity measured at multiple intervals during a single exhalation in manJournal of Applied Physiology, 1977
- A THEORETICAL AND EXPERIMENTAL ANALYSIS OF ANOMALIES IN THE ESTIMATION OF PULMONARY DIFFUSING CAPACITY BY THE SINGLE BREATH METHODQuarterly Journal of Experimental Physiology and Cognate Medical Sciences, 1961