Instantaneous blood flow responses to positive end-expiratory pressure with spontaneous ventilation.
- 1 June 1979
- journal article
- research article
- Published by Wolters Kluwer Health in Circulation
- Vol. 59 (6) , 1312-1318
- https://doi.org/10.1161/01.cir.59.6.1312
Abstract
Variable hemodynamic responses to positive end-expiratory pressure (PEEP) with spontaneous ventilation have been reported. To clarify these responses, 15 awake patients were studied using a catheter-tip velocity transducer to record phasic aortic root blood flow continuously before, during and after PEEP (10 cm H2O) applied with a face mask. Central blood volume and effective ventricular filling pressures were measured. Phasic pulmonary artery blood flow was also simultaneously recorded in three of these patients. PEEP produced an acute aortic blood flow reduction, detected within one respiratory cycle. Stroke volume decreased 12%, and since heart rate was unchanged, cardiac output also declined (p less than 0.05). Inspiratory-to-expiratory aortic flow changes were less during PEEP. In contrast, inspiratory-to-expiratory pulmonary artery flow alterations were exaggerated due to a marked flow decline during expiration. Central blood volume and effective left ventricular filling pressure decreased 9% and 19%, respectively (p less than 0.05 in all patients). The decrease in pulmonary artery flow was associated with a decrease in central blood volume in the three patients in whom pulmonary flow was measured. PEEP promptly reduces cardiac output during spontaneous ventilation, related to a decrease in pulmonary flow in expiration.This publication has 13 references indexed in Scilit:
- Coronary Circulatory Effects of Increased Intrathoracic Pressure in Intact DogsChest, 1977
- Analog computer assisted beat-by-beat measurement of stroke volume and related variables in manCardiovascular Research, 1976
- Positive end-expiratory pressureThe Journal of Thoracic and Cardiovascular Surgery, 1973
- Effects of the Valsalva maneuver on blood flow in the thoracic aorta in man.Journal of Applied Physiology, 1966
- Stroke volume in conscious dogs; effect of respiration, posture, and vascular occlusionJournal of Applied Physiology, 1965
- Relation between pressure and diameter in main pulmonary artery of manJournal of Applied Physiology, 1963
- Relation Between Pressure and Diameter in the Ascending Aorta of ManCirculation Research, 1962
- Components of the "Central" Blood Volume in the DogCirculation Research, 1960
- VENTILATORY MECHANICS IN PULMONARY EDEMA IN MAN1Journal of Clinical Investigation, 1958
- STUDIES ON THE CIRCULATIONAmerican Journal of Physiology-Legacy Content, 1932