A Nonlinear Axisymmetric Model With Fluid–Wall Interactions for Steady Viscous Flow in Stenotic Elastic Tubes
- 1 October 1999
- journal article
- research article
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 121 (5) , 494-501
- https://doi.org/10.1115/1.2835078
Abstract
Arteries with high-grade stenoses may compress under physiologic conditions due to negative transmural pressure caused by high-velocity flow passing through the stenoses. To quantify the compressive conditions near the stenosis, a nonlinear axisymmetric model with fluid–wall interactions is introduced to simulate the viscous flow in a compliant stenotic tube. The nonlinear elastic properties of the tube (tube law) are measured experimentally and used in the model. The model is solved using ADINA (Automatic Dynamic Incremental Nonlinear Analysis), which is a finite element package capable of solving problems with fluid–structure interactions. Our results indicate that severe stenoses cause critical flow conditions such as negative pressure and high and low shear stresses, which may be related to artery compression, plaque cap rupture, platelet activation, and thrombus formation. The pressure field near a stenosis has a complex pattern not seen in one-dimensional models. Negative transmural pressure as low as −24 mmHg for a 78 percent stenosis by diameter is observed at the throat of the stenosis for a downstream pressure of 30 mmHg. Maximum shear stress as high as 1860 dyn/cm2 occurs at the throat of the stenoses, while low shear stress with reversed direction is observed right distal to the stenosis. Compressive stresses are observed inside the tube wall. The maximal principal stress and hoop stress in the 78 percent stenosis are 80 percent higher than that from the 50 percent stenosis used in our simulation. Flow rates under different pressure drop conditions are calculated and compared with experimental measurements and reasonable agreement is found for the prebuckling stage.Keywords
This publication has 34 references indexed in Scilit:
- A Fluid-Structure Interaction Finite Element Analysis of Pulsatile Blood Flow Through a Compliant Stenotic ArteryJournal of Biomechanical Engineering, 1999
- Particle motion within in vitro models of stenosed internal carotid and left anterior descending coronary arteries.Annals of Biomedical Engineering, 1998
- Effects of Frictional Losses and Pulsatile Flow on the Collapse of Stenotic ArteriesJournal of Biomechanical Engineering, 1997
- Correlation of poststenotic hyperemic coronary flow velocity and pressure with abnormal stress myocardial perfusion imaging in coronary artery diseaseThe American Journal of Cardiology, 1996
- Collapse of diseased arteries with eccentric cross sectionJournal of Biomechanics, 1993
- Plaque Hemorrhages, Their Genesis and Their Role in Supra-Plaque Thrombosis and AtherogenesisPublished by Springer Nature ,1990
- Effect of stenosis on wall motion. A possible mechanism of stroke and transient ischemic attack.Arteriosclerosis: An Official Journal of the American Heart Association, Inc., 1989
- The effects of wall thickness, axial strain and end proximity on the pressure-area relation of collapsible tubesJournal of Biomechanics, 1987
- Plaque fissuring--the cause of acute myocardial infarction, sudden ischaemic death, and crescendo angina.Heart, 1985
- Inhibition of coronary blood flow by a vascular waterfall mechanism.Circulation Research, 1975