Blood loss in total hip replacement
- 1 December 1991
- journal article
- review article
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 111 (1) , 34-38
- https://doi.org/10.1007/bf00390191
Abstract
Two hundred and twelve total hip replacements performed in one clinic over 1 year were reviewed. The mean operative time was 89 min and mean total blood loss 1090 ml. Homologous blood was administered to 74% of the patients. Blood loss was dependent on sex, body weight and height, but these correlations were eliminated when blood loss was related to estimated blood volume. There was no correlation to age. There was a positive correlation between operative time and intraoperative blood loss, but not between any of these factors and postoperative blood loss. Operative time varied significantly between surgeons, but there was no correlation between surgeon's experience and operative time or blood loss. Despite a mean of only 12 total hip replacements per surgeon, both operative time and blood loss were small compared to what was found in other studies. The use of a posterior approach is believed to contribute to a shorter operative time as well as to moderate blood loss. Intraoperative blood loss was less under epidural than under general anaesthesia, but in contrast to others we found higher postoperative blood loss after epidural anaesthesia.Keywords
This publication has 31 references indexed in Scilit:
- Heparin/dihydroergotamine for venous thrombosis prophylaxis: comparison of low-dose heparin and low molecular weight heparin in hip surgeryBritish Journal of Surgery, 1988
- Blood substitution and complement activationActa Anaesthesiologica Scandinavica, 1987
- Activation of cascade systems by hip arthroplasty: No difference between fixation with and without cementActa Orthopaedica, 1987
- Three Per Cent Dextran‐60 as a Plasma Substitute in Blood Component TherapyActa Anaesthesiologica Scandinavica, 1985
- Hypotensive Anesthesia, Thromboprophylaxis and Postoperative Thromboembolism in Total Hip ArthroplastyActa Anaesthesiologica Scandinavica, 1984
- Anesthetic Techniques and Surgical Blood Loss in Total Hip ArthroplastyActa Anaesthesiologica Scandinavica, 1982
- Deep Vein Thrombosis Following Hip Surgery:Relation to Activated Factor X Inhibitor Activity: Effect of Heparin and DextranActa Orthopaedica, 1982
- Effects of Tocainide, an Oral Analogue of Lidocaine, on Thromboembolism after Total Hip ReplacementUpsala Journal of Medical Sciences, 1981
- Effect of Epidural Versus General Anaesthesia on Calf Blood FlowActa Anaesthesiologica Scandinavica, 1980
- Hypotensive Anesthesia for Total Hip ArthroplastyAnesthesiology, 1978