Direct Evidence of Ionic Fluxes Across Ion-Selective Membranes: A Scanning Electrochemical Microscopic and Potentiometric Study
- 3 April 2001
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 73 (9) , 2104-2111
- https://doi.org/10.1021/ac000922k
Abstract
Scanning electrochemical microscopy (SECM) supplemented with potentiometric measurements was used to follow the time-dependent buildup of a steady-state diffusion layer at the aqueous-phase boundary of lead ion-selective electrodes (ISEs). Differential pulse voltammetry is adapted to SECM for probing the local concentration profiles at the sample side of solvent polymeric membranes. Major factors affecting the membrane transport-related surface concentrations were identified from SECM data and the potentiometric transients obtained under different experimental conditions (inner filling solution composition, membrane thickness, surface pretreatment). The amperometrically determined surface concentrations correlated well with the lower detection limits of the lead ion-selective electrodes.Keywords
This publication has 38 references indexed in Scilit:
- Properties of PVC based membranes used in ion-selective electrodesPublished by Elsevier ,2002
- Ion sensors: current limits and new trendsAnalytica Chimica Acta, 1999
- Stability of preplated mercury coated platinum and carbon fibre microelectrodesAnalytica Chimica Acta, 1996
- Transport processes in membranes containing neutral ion carriers, positive ion complexes, negative mobile sites, and ion pairsThe Journal of Physical Chemistry, 1993
- Investigation of silver iodide-based ion-selective membranes by scanning electrochemical microscopyAnalytica Chimica Acta, 1993
- Detection limit of ion-selective bulk optodes and corresponding electrodesAnalytica Chimica Acta, 1993
- Radioimmunologic determination of human C-peptide and proinsulin in plasma with anti-C-peptide serum after prepurification by high-performance liquid chromatographyAnalytical Chemistry, 1987
- Potentiostat with a positive feedback IR compensation and a high sensitivity current follower indicator circuit for direct determination of high second-order rate constantsAnalytical Chemistry, 1982
- A simple continuous method for calibration and measurement with ion-selective electrodesAnalytica Chimica Acta, 1976
- Selectrode—the universal ion-selective electrode: Part VI. The calcium(II) selectrode employing a new ion exchanger in a nonporous membrane and a solid-state reference systemAnalytica Chimica Acta, 1973