A Specific Laboratory Test for the Diagnosis of Melancholia
- 1 January 1981
- journal article
- research article
- Published by American Medical Association (AMA) in Archives of General Psychiatry
- Vol. 38 (1) , 15-22
- https://doi.org/10.1001/archpsyc.1981.01780260017001
Abstract
• Four hundred thirty-eight subjects underwent an overnight dexamethasone suppression test (DST) to standardize the test for the diagnosis of melancholia (endogenous depression). Abnormal plasma cortisol concentrations within 24 hours after dexamethasone administration occurred almost exclusively in melancholic patients. The best plasma cortisol criterion concentration, above which a DST result may be considered abnormal, was 5 ug/dL. The optimal dose of dexamethasone was 1 rather than 2 mg. Two blood samples obtained at 4 and 11 PM after dexamethasone administration detected 98% of the abnormal test results. This version of the DST identified melancholic patients with a sensitivity of 67% and a specificity of 96%. Baseline nocturnal plasma cortisol concentrations were not useful. Abnormal DST results were found with similar frequency among outpatients and inpatients with melancholia; but they were not related to age, sex, recent use of psychotropic drugs, or severity of depressive symptoms. Extensive evidence validates this practical test for the diagnosis of melancholia.This publication has 13 references indexed in Scilit:
- Log-Normal DistributionsPublished by Cambridge University Press (CUP) ,1999
- Response to Dexamethasone and Subtype of DepressionArchives of General Psychiatry, 1980
- Resistance to inhibiting effect of dexamethasone in patients with endogenous depressionActa Psychiatrica Scandinavica, 1980
- Tricyclic AntidepressantsNew England Journal of Medicine, 1978
- The Classification of Depressions: A Review of Contemporary ConfusionThe British Journal of Psychiatry, 1976
- Resistance to Suppression by Dexamethasone of Plasma 11-O.H.C.S. Levels in Severe Depressive IllnessBMJ, 1968
- Some Studies of the Protein-Binding of Steroids and Their Application to the Routine Micro and Ultramicro Measurement of Various Steroids in Body Fluids by Competitive Protein-Binding Radioassay1Journal of Clinical Endocrinology & Metabolism, 1967
- Normal or Log-normal: Appropriate DistributionsNature, 1967
- Predictive Value of a Single Diagnostic Test in Unselected PopulationsNew England Journal of Medicine, 1966
- A RATING SCALE FOR DEPRESSIONJournal of Neurology, Neurosurgery & Psychiatry, 1960