Accuracy of GDx VCC, HRT I, and clinical assessment of stereoscopic optic nerve head photographs for diagnosing glaucoma
- 11 October 2006
- journal article
- research article
- Published by BMJ in British Journal of Ophthalmology
- Vol. 91 (3) , 313-318
- https://doi.org/10.1136/bjo.2006.096586
Abstract
To determine and compare the accuracy and reproducibility of GDx variable cornea compensation (VCC) scanning laser polarimetry (SLP) with VCC, Heidelberg retina tomograph (HRT) I confocal scanning laser ophthalmoscopy (CSLO), and clinical assessment of stereoscopic optic nerve head (ONH) photographs for diagnosing glaucoma. One eye each of 40 healthy subjects, 48 glaucoma patients, and six patients with ocular hypertension were measured with SLP-VCC and CSLO. Simultaneous stereoscopic ONH photographs were also obtained. Sixteen photographs of healthy and glaucomatous eyes were duplicated for assessing intraobserver agreement. Four glaucoma specialists, four general ophthalmologists, four residents in ophthalmology, and four optometrists classified the ONH photographs as normal or glaucomatous. For SLP-VCC, the nerve fiber indicator (NFI) was evaluated. For CSLO, the Moorfields regression analysis (MRA) and the Bathija linear discriminant function (LDF) were used. Sensitivity, specificity, percentage of correctly classified eyes, and intra- and interobserver agreement, expressed as kappa (kappa) were calculated. SLP-VCC had the highest diagnostic accuracy, with a sensitivity, specificity, and overall correct classification of 91.7%, 95.0% and 93.2%, respectively. CSLO, expressed as Bathija LDF and MRA, had a diagnostic accuracy comparable to glaucoma specialists and general ophthalmologists with an overall accuracy of 89.8%, 86.4%, 86.7% and 85.2%, respectively. Residents classified the fewest eyes correctly. Intraobserver agreement for classifying the ONH photographs ranged between 0.48 (within residents) and 0.78 (within glaucoma specialists). The interobserver agreement ranged between 0.45 (between residents) and 0.74 (between glaucoma specialists). The agreement between observers and CSLO MRA (kappa, 0.68) was statistically significantly higher (p<0.001; paired t-test) than between observers and SLP-VCC NFI (kappa, 0.60) and CSLO Bathija LDF (kappa, 0.62). Automated analysis of measurements with GDx VCC and HRT had a similar diagnostic accuracy for glaucoma as classification of stereoscopic ONH photographs by glaucoma specialists, thus bringing all eye-care professionals to this desirable level. The intra- and interobserver agreement for ONH analysis was only moderate to good. We think these imaging techniques may assist clinicians in diagnosing glaucoma.Keywords
This publication has 12 references indexed in Scilit:
- Diagnostic accuracy of the GDx VCC for glaucomaOphthalmology, 2004
- Subjective and objective optic nerve assessment in African Americans and whites.Investigative Opthalmology & Visual Science, 2004
- Comparison of the GDx VCC Scanning Laser Polarimeter, HRT II ConfocalScanning Laser Ophthalmoscope, and Stratus OCT Optical Coherence Tomographfor the Detection of GlaucomaArchives of Ophthalmology (1950), 2004
- Comparison of data analysis tools for detection of glaucoma with the heidelberg retina tomographOphthalmology, 2003
- Comparison of optic nerve imaging methods to distinguish normal eyes from those with glaucoma.2002
- Identifying early glaucomatous changes: Comparison between expert clinical assessment of optic disc photographs and confocal scanning ophthalmoscopyOphthalmology, 2000
- Identification of early glaucoma cases with the scanning laser ophthalmoscopeOphthalmology, 1998
- Agreement among Optometrists, Ophthalmologists, and Residents in Evaluating the Optic Disc for GlaucomaOphthalmology, 1994
- Expert Agreement in Evaluating the Optic Disc for GlaucomaOphthalmology, 1992
- Quantitative assessment of the optic nerve head with the laser tomographic scannerInternational Ophthalmology, 1989