Reproducibility of measurements of cardiac output in newborn infants by Doppler ultrasound.
Open Access
- 1 January 1990
- journal article
- research article
- Published by BMJ in Archives of Disease in Childhood
- Vol. 65 (1 Spec No) , 15-19
- https://doi.org/10.1136/adc.65.1_spec_no.15
Abstract
Interobserver reproducibility in deriving cardiac output by measuring aortic blood flow velocity and diameter with imaging and Doppler ultrasound was investigated in 20 healthy infants born at full term. Aortic diameter was measured in three ways. Mean blood flow velocity was measured at three sites with both continuous wave and pulsed Doppler. Two observers carried out each study independently. Intraobserver reproducibility was investigated in 12 infants using the suprasternal site for measuring blood flow velocity. The most reproducible determination of cardiac output was found when the suprasternal site with continuous wave Doppler was used for measurement of blood flow velocity and M mode trailing edge to leading edge echocardiography was used for diameter. Normal mean (2 SD) cardiac output is 231 (77) ml/kg/min. Technical difficulties in measuring aortic diameter accurately limit direct comparison between infants.This publication has 16 references indexed in Scilit:
- Pulsed‐Doppler Assessment of Ascending Aortic Flow Velocity in Newborns and Infants: Clinical ApplicationsEchocardiography, 1988
- Cardiac output in newborn infants with transient myocardial dysfunctionThe Journal of Pediatrics, 1985
- Assessment of aortic blood flow velocities with continuous wave Doppler ultrasound in the neonate and young childJournal of the American College of Cardiology, 1985
- Digital subtraction angiography in patients with transposition of the great arteries after surgical repairJournal of the American College of Cardiology, 1985
- Noninvasive Measurement of Cardiac Output by Continuous-Wave Doppler Echocardiography: Initial Experience and Review of the LiteratureMayo Clinic Proceedings, 1984
- Noninvasive Measurement of Cardiac Output in Healthy Preterm and Term Newborn InfantsAmerican Journal of Perinatology, 1984
- Noninvasive pulsed Doppler determination of cardiac output in neonates and childrenThe Journal of Pediatrics, 1982
- Perioperative echocardiographic evaluation of cardiovascular function: assessment of changing hemodynamic state.Circulation, 1980
- SERIAL MEASUREMENTS OF THORACIC IMPEDANCE AND CARDIAC OUTPUT IN HEALTHY NEONATES AFTER NORMAL DELIVERY AND CAESAREAN SECTIONActa Paediatrica, 1979
- Accuracy and limitations of the ultrasonic Doppler blood velocimeter and zero crossing detectorUltrasound in Medicine & Biology, 1975