Prevalence and prognosis of shunting across patent foramen ovale during acute respiratory distress syndrome*
- 1 September 2010
- journal article
- Published by Wolters Kluwer Health in Critical Care Medicine
- Vol. 38 (9) , 1786-1792
- https://doi.org/10.1097/ccm.0b013e3181eaa9c8
Abstract
Right-to-left shunting across a patent foramen ovale may occur in acute respiratory distress syndrome as a result of pulmonary hypertension and positive-pressure mechanical ventilation. The shunt may worsen the hypoxemia. The objective of our study was to determine the prevalence, clinical implications, and prognosis of patent foramen ovale shunting during acute respiratory distress syndrome. Prospective study. Medical intensive care unit of a university hospital in Créteil, France. Two hundred three consecutive patients with acute respiratory distress syndrome. Patent foramen ovale shunting was detected by using transesophageal echocardiography with modified gelatin contrast. Moderate-to-large shunting was defined as right-to-left passage of at least 10 bubbles through a valve-like structure within three cardiac cycles after complete opacification of the right atrium. In 85 patients without and 31 with shunting, the influence of the positive end-expiratory pressure level on shunting was studied. The prevalence of moderate-to-large patent foramen ovale shunting was 19.2% (39 patients). Compared to those in the group without shunting, the patients in group with shunting had larger right ventricle dimensions, higher pulmonary artery systolic pressure, and a higher prevalence of cor pulmonale. Compared to patients without shunting, patients with shunting had a poorer Pa(O(2))/Fi(O(2)) ratio response to positive end-expiratory pressure, more often required prone positioning and nitric oxide as adjunctive interventions, and had fewer ventilator-free and intensive care unit-free days within the first 28 days. Moderate-to-large patent foramen ovale shunting occurred in 19.2% of patients with acute respiratory distress syndrome, in keeping with findings from autopsy studies. Patent foramen ovale was associated with a poor oxygenation response to positive end-expiratory pressure, greater use of adjunctive interventions, and a longer intensive care unit stay.Keywords
This publication has 37 references indexed in Scilit:
- Incidence and prognostic value of right ventricular failure in acute respiratory distress syndromeIntensive Care Medicine, 2008
- Comparison of prone positioning and high-frequency oscillatory ventilation in patients with acute respiratory distress syndrome*Critical Care Medicine, 2005
- Patent foramen ovale: a review of associated conditions and the impact of physiological sizeJournal of the American College of Cardiology, 2001
- Acute cor pulmonale in acute respiratory distress syndrome submitted to protective ventilation: Incidence, clinical implications, and prognosisCritical Care Medicine, 2001
- Hemodynamic profile in severe ARDS: results of the European Collaborative ARDS StudyIntensive Care Medicine, 1998
- The American-European Consensus Conference on ARDS. Definitions, mechanisms, relevant outcomes, and clinical trial coordination.American Journal of Respiratory and Critical Care Medicine, 1994
- Inhaled Nitric Oxide for the Adult Respiratory Distress SyndromeNew England Journal of Medicine, 1993
- Profound hypoxemia precipitated by positive end-expiratory pressureCritical Care Medicine, 1992
- Incidence and Size of Patent Foramen Ovale During the First 10 Decades of Life: An Autopsy Study of 965 Normal HeartsPublished by Elsevier ,1984
- Postoperative Hypoxemia Due to Opening of a Patent Foramen Ovale Confirmed by a Right Atrium-Left Atrium Pressure Gradient during Mechanical VentilationAnesthesiology, 1982