Maintaining the Unit of Voltage at PTB via the Josephson Effect
- 1 December 1974
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 23 (4) , 271-275
- https://doi.org/10.1109/tim.1974.4314290
Abstract
In Section I a report on high precision voltage comparisons between the mean EMF of the former PTB voltage standard (consisting of a group of 39 saturated Weston cells) and the Josephson reference voltage is presented. The experiments were carried out with a total uncertainty (1 σ) of 4 parts in 108. The measured rate of change of the mean EMF during a 1¾ year period was - 1.3 X 10-7 V per year. This voltage stability is sufficient to maintain the unit of voltage by this group of standard cells for several months until a new comparison with the Josephson reference voltage becomes necessary. Due to the effects of thermal EMF's in the millivolt circuit of the measuring system used at present, the Josephson reference voltage (≈ 3 . mV) is only stable during a short time. In Section II a prototype cryogenic voltage standard developed at PTB is described. By immersing the main measurement components into the superfluid liquid helium bath, a long term voltage stability can be achieved. These components include the cryogenic resistive divider, consisting of a new copper alloy, and the SQUID null detector. The resistance ratio of the cryogenic resistive divider of 320:1 is determined by a ten-decade inductive voltage comparator operating at 84 Hz. The effects of power dissipation introduce only errors of second order because the currents in the calibration mode and the measurement mode are the same.Keywords
This publication has 9 references indexed in Scilit:
- Resistance Measurements at Frequencies below 10 HzIEEE Transactions on Instrumentation and Measurement, 1974
- Precise resistance ratio measurements using a superconducting dc ratio transformerReview of Scientific Instruments, 1973
- Volt Maintenance at NBS via 2e/h: A New Definition of the NBS VoltMetrologia, 1973
- Recent Progress of the 2e/h Measurement at PTBIEEE Transactions on Instrumentation and Measurement, 1972
- Monitoring the NSL Standard of EMF Using the AC Josephson EffectMetrologia, 1972
- Low Temperature Voltage Divider and Null DetectorReview of Scientific Instruments, 1972
- Recent NPL Work on the AC Josephson Effect as a Voltage StandardIEEE Transactions on Instrumentation and Measurement, 1972
- Author's Reply to Comment on ``The Application of the Direct Current Comparator to a Seven-Decade Potentiometer''IEEE Transactions on Instrumentation and Measurement, 1971
- The Accuracy of Series and Parallel Connections of Four-Terminal ResistorsIEEE Transactions on Instrumentation and Measurement, 1967