Influence of 90-day simulated microgravity on human tendon mechanical properties and the effect of resistive countermeasures
- 1 June 2005
- journal article
- clinical trial
- Published by American Physiological Society in Journal of Applied Physiology
- Vol. 98 (6) , 2278-2286
- https://doi.org/10.1152/japplphysiol.01266.2004
Abstract
While microgravity exposure is known to cause deterioration of skeletal muscle performance, little is known regarding its effect on tendon structure and function. Hence, the aims of this study were to investigate the effects of simulated microgravity on the mechanical properties of human tendon and to assess the effectiveness of resistive countermeasures in preventing any detrimental effects. Eighteen men (aged 25–45 yr) underwent 90 days of bed rest: nine performed resistive exercise during this period (BREx group), and nine underwent bed rest only (BR group). Calf-raise and leg-press exercises were performed every third day using a gravity-independent flywheel device. Isometric plantar flexion contractions were performed by using a custom-built dynamometer, and ultrasound imaging was used to determine the tensile deformation of the gastrocnemius tendon during contraction. In the BR group, tendon stiffness estimated from the gradient of the tendon force-deformation relation decreased by 58% (preintervention: 124 ± 67 N/mm; postintervention: 52 ± 28 N/mm; P < 0.01), and the tendon Young's modulus decreased by 57% postintervention ( P < 0.01). In the BREx group, tendon stiffness decreased by 37% (preintervention: 136 ± 66 N/mm; postintervention: 86 ± 47 N/mm; P < 0.01), and the tendon Young's modulus decreased by 38% postintervention ( P < 0.01). The relative decline in tendon stiffness and Young's modulus was significantly ( P < 0.01) greater in the BR group compared with the BREx group. Unloading decreased gastrocnemius tendon stiffness due to a change in tendon material properties, and, although the exercise countermeasures did attenuate these effects, they did not completely prevent them. It is suggested that the total loading volume was not sufficient to completely prevent alterations in tendon mechanical properties.Keywords
This publication has 67 references indexed in Scilit:
- Hypertrophy of chronically unloaded muscle subjected to resistance exerciseJournal of Applied Physiology, 2004
- Effects of resistance training during bed rest on the viscoelastic properties of tendon structures in the lower limbScandinavian Journal of Medicine & Science in Sports, 2004
- Muscle hypertrophy following 5‐week resistance training using a non‐gravity‐dependent exercise systemActa Physiologica Scandinavica, 2004
- Resistance Training in SpaceInternational Journal of Sports Medicine, 1997
- Changes in muscle function in response to 10 days of lower limb unloading in humansActa Physiologica Scandinavica, 1996
- Physiological cross‐sectional area of human leg muscles based on magnetic resonance imagingJournal of Orthopaedic Research, 1992
- Correlation of Physiological Cross-Sectional Areas of Muscle and TendonJournal of Hand Surgery (European Volume), 1991
- The Biomechanical and Biochemical Properties of Swine Tendons — Long Term Effects of Exercise on the Digital ExtensorsConnective Tissue Research, 1980
- Functional Properties of Knee Ligaments and Alterations Induced by ImmobilizationPublished by Wolters Kluwer Health ,1977
- Connective tissue response to immobilityArthritis & Rheumatism, 1975