Restoration of gamma camera-based nuclear medicine images
- 1 January 1989
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 8 (4) , 354-363
- https://doi.org/10.1109/42.41488
Abstract
Experiments were conducted using a Siemens Rota camera to study the applicability of two linear shift-invariant (LSI) filters, namely, the Wiener and power spectrum equalization filters, for restoration of planar projections and single-photon-emission computed tomography (SPECT) images. In the restoration scheme, the system transfer function, computed from a line source image, is modeled by a 2-D Gaussian function. The noise power spectrum is modeled as a constant for planar images and as a ramp for SPECT images. The filters have been applied to restore computer-simulated 1-D and 2-D projections and SPECT images of two simple phantoms, 2-D projections of two phantoms obtained from the Siemens Rota camera, and SPECT images of a cardiac phantom obtained from the Siemens Rota camera. The filters are shown to perform partial restoration. Considerable noise suppression and detail enhancement have been observed in the restored images. quantitative measurements such as root-mean-squared error and contrast ratio have been used for objective analysis of the results, which are encouraging.Keywords
This publication has 27 references indexed in Scilit:
- Optimal preprocessing Butterworth-Wiener filter for Tl-201 myocardial SPECTEuropean Journal of Nuclear Medicine and Molecular Imaging, 1987
- The noise power spectrum of CT imagesPhysics in Medicine & Biology, 1987
- Analysis of x-ray computed tomography images using the noise power spectrum and autocorrelation functionPhysics in Medicine & Biology, 1984
- Sampling from binomial and poisson distributions: A method with bounded computation timesComputing, 1980
- Detectability in computed tomographic imagesMedical Physics, 1979
- A study of the application of a deconvolution method to scintigraphyPhysics in Medicine & Biology, 1979
- The noise power spectrum in computed X-ray tomographyPhysics in Medicine & Biology, 1978
- The Characteristics of Computed Tomographic Reconstruction Noise and Their Effect on DetectabilityIEEE Transactions on Nuclear Science, 1978
- Fundamental Limitations In Linear Invariant Restoration Of Atmospherically Degraded ImagesPublished by SPIE-Intl Soc Optical Eng ,1976
- Restoring with Maximum Likelihood and Maximum Entropy*Journal of the Optical Society of America, 1972