Molecular rotors—fluorescent biosensors for viscosity and flow
Top Cited Papers
- 12 April 2007
- journal article
- emerging area
- Published by Royal Society of Chemistry (RSC) in Organic & Biomolecular Chemistry
- Vol. 5 (11) , 1669-1678
- https://doi.org/10.1039/b618415d
Abstract
Viscosity is a measure of the resistance of a fluid against gradients in flow (shear rate). Both flow and viscosity play an important role in all biological systems from the microscopic (e.g., cellular) to the systemic level. Many methods to measure viscosity and flow have drawbacks, such as the tedious and time-consuming measurement process, expensive instrumentation, or the restriction to bulk sample sizes. Fluorescent environment-sensitive dyes are known to show high sensitivity and high spatial and temporal resolution. Molecular rotors are a group of fluorescent molecules that form twisted intramolecular charge transfer (TICT) states upon photoexcitation and therefore exhibit two competing deexcitation pathways: fluorescence emission and non-radiative deexcitation from the TICT state. Since TICT formation is viscosity-dependent, the emission intensity of molecular rotors depends on the solvent's viscosity. Furthermore, shear-stress dependency of the emission intensity was recently described. Although the photophysical processes are widely explored, the practical application of molecular rotors as sensors for viscosity and the fluid flow introduce additional challenges. Intensity-based measurements are influenced by fluid optical properties and dye concentration, and solvent–dye interaction requires calibration of the measurement system to a specific solvent. Ratiometric dyes and measurement systems help solve these challenges. In addition, the combination of molecular rotors with specific recognition groups allows them to target specific sites, for example the cell membrane or cytoplasm. Molecular rotors are therefore emerging as new biosensors for both bulk and local microviscosity, and for flow and fluid shear stress on a microscopic scale and with real-time response.Keywords
This publication has 65 references indexed in Scilit:
- Synthesis and use of an in-solution ratiometric fluorescent viscosity sensorNature Protocols, 2007
- A Ratiometric Fluorophotometer for Fluorescence-Based Viscosity Measurement with Molecular RotorsSensor Letters, 2005
- Sensing of Flow and Shear Stress Using Fluorescent Molecular RotorsSensor Letters, 2005
- Shear stress inhibits apoptosis of human endothelial cellsFEBS Letters, 1996
- Membrane aging during cell growth ascertained by laurdan generalized polarizationExperimental Cell Research, 1992
- Membrane fluidity, reactive oxygen species, and cell-mediated immunity: Implications in nutrition and diseaseMedical Hypotheses, 1992
- Investigation of the Defense System of the Human Lungs With Ferrimagnetic ParticlesJournal of Aerosol Medicine, 1992
- Non-radiative deactivation channels of molecular rotorsJournal of Photochemistry and Photobiology A: Chemistry, 1989
- Cytoplasmic motions, rheology, and structure probed by a novel magnetic particle method.The Journal of cell biology, 1985
- Fluidity parameters of lipid regions determined by fluorescence polarizationBiochimica et Biophysica Acta (BBA) - Reviews on Biomembranes, 1978