Automated assignment of charge states from resolved isotopic peaks for multiply charged ions
- 1 January 1995
- journal article
- Published by American Chemical Society (ACS) in Journal of the American Society for Mass Spectrometry
- Vol. 6 (1) , 52-56
- https://doi.org/10.1016/1044-0305(94)00091-d
Abstract
The recent proliferation of electrospray as an ionization method has greatly increased the ability to perform analyses of large biomolecules by using mass spectrometry. The major advantage of electrospray is the ability to produce multiply charged ions, which brings large molecules down to a mass-to-charge ratio range amenable to most instruments. Multiple charging is also a disadvantage because mass (m) becomes ambiguous unless charge (z) can be assigned. This is typically performed with simple algorithms that use multiple peaks of the same m and different z, but these methods are difficult to apply to complex mixtures and not applicable when only one z appears for each m. The use of mass analyzers with higher resolving powers, like the Fourier transform mass spectrometer, allows resolution of isotopic peaks, providing an internal 1-Da mass scale that can be used for unambiguous charge assignment. Manual assignment of charge state from the isotopic peaks is time consuming and becomes inaccurate when either the signal level or resolving power are low. For these cases, computer algorithms based on pattern recognition techniques have been developed to assist in assignment of charge states to isotopic clusters. These routines provide for more rapid analysis with higher accuracy than available manually.Keywords
This publication has 30 references indexed in Scilit:
- Identifying Charge States of Peptides in Liquid Chromatography/Electrospray Ionization Mass SpectrometryAnalytical Chemistry, 1994
- Accurate mass determination of a high molecular weight protein using electrospray lonization with a magnetic sector instrumentRapid Communications in Mass Spectrometry, 1993
- Three‐dimensional deconvolution of multiply charged spectraRapid Communications in Mass Spectrometry, 1993
- Fourier transform mass spectrometryMass Spectrometry Reviews, 1992
- Analysis of antibodies and other large glycoproteins in the mass range of 150,000-200,000 daltons by electrospray ionization mass spectrometryAnalytical Chemistry, 1992
- Electrospray ionization in the strong magnetic field of a Fourier transform ion cyclotron resonance mass spectrometerAnalytical Chemistry, 1992
- Charge determination of product ions formed from collision-induced dissociation of multiply protonated molecules via ion/molecule reactionsAnalytical Chemistry, 1991
- Sustained off-resonance irradiation for collision-activated dissociation involving Fourier transform mass spectrometry. Collision-activated dissociation technique that emulates infrared multiphoton dissociationAnalytica Chimica Acta, 1991
- Fourier transform ion cyclotron resonance mass spectrometry: the teenage yearsAnalytical Chemistry, 1991
- Electrospray ionization with Fourier‐transform mass spectrometry. Charge state assignment from resolved isotopic peaksJournal of Mass Spectrometry, 1990