Paper tests for occult blood in faeces and some observations on the fate of swallowed red cells
Open Access
- 1 July 1961
- journal article
- research article
- Published by BMJ in Journal of Clinical Pathology
- Vol. 14 (4) , 436-440
- https://doi.org/10.1136/jcp.14.4.436
Abstract
Paper tests for occult blood were assessed on faecal specimens from adults. An orthotolidine/sodium perborate and a modified orthotolidine/peroxide test were found to be reasonably satisfactory. The Hematest and Occultest tablets and a paper guaiac test were unsatisfactory. A large number of false positive results was obtained in children and infants. It is suggested that this might be due to meat derivatives reaching the faeces more easily in the young. Red cells labelled with either Cr51 or Fe59 were swallowed by human volunteers. Although between 45% and 73% of the red cell iron reappeared in the faeces, the peroxidase activity of the labelled material dropped six-fold on passage through the alimentary canal.Keywords
This publication has 7 references indexed in Scilit:
- A Trial of Tablet Substitutes for the Gregersen TestJournal of Clinical Pathology, 1959
- Measurement of Red-cell Loss from Gastro-intestinal Tract, using Radioactive ChromiumBMJ, 1958
- EVALUATION OF TESTS FOR OCCULT BLOOD IN THE FECESJAMA, 1957
- A modified technique for the detection of occult blood in faeces.1955
- The carcinogenic activity of dihydroxybenzidine; further investigations.1953
- The benzidine test for occult blood in faces.1952
- THE TAGGING OF RED CELLS AND PLASMA PROTEINS WITH RADIOACTIVE CHROMIUM 1Journal of Clinical Investigation, 1950