Peptide Quantification Using 8-Plex Isobaric Tags and Electron Transfer Dissociation Tandem Mass Spectrometry
- 20 January 2009
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 81 (4) , 1693-1698
- https://doi.org/10.1021/ac8019202
Abstract
Isobaric tags for absolute and relative quantitation (iTRAQ) allow for simultaneous relative quantification of peptides from up to eight different samples. Typically peptides labeled with 8-plex iTRAQ tags are pooled and fragmented using beam-type collision activated dissociation (CAD) which, in addition to cleaving the peptide backbone bonds, cleaves the tag to produce reporter ions. The relative intensities of the reporters are directly proportional to the relative abundances of each peptide in the solution phase. Recently, studies using the 4-plex iTRAQ tagging reagent demonstrated that electron transfer dissociation (ETD) of 4-plex iTRAQ labeled peptides cleaves at the N−Cα bond in the tag and allows for up to three channels of quantification. In this paper we investigate the ETD fragmentation patterns of peptides labeled with 8-plex iTRAQ tags. We demonstrate that upon ETD, peptides labeled with 8-plex iTRAQ tags fragment to produce unique reporter ions that allow for five channels of quantification. ETD-MS/MS of these labeled peptides also produces a peak at 322 m/z which, upon resonant excitation (CAD), gives rise to all eight iTRAQ reporter ions and allows for eight channels of quantification. Comparison of this method to beam-type CAD quantification shows a good correlation (y = 0.91x + 0.01, R2 = 0.9383).Keywords
This publication has 29 references indexed in Scilit:
- Peptide and Protein Quantification Using iTRAQ with Electron Transfer DissociationJournal of the American Society for Mass Spectrometry, 2008
- Electron Transfer Dissociation of iTRAQ Labeled Peptide IonsJournal of Proteome Research, 2008
- A Proteomics Grade Electron Transfer Dissociation-Enabled Hybrid Linear Ion Trap-Orbitrap Mass SpectrometerJournal of Proteome Research, 2008
- Comprehensive Comparison of Collision Induced Dissociation and Electron Transfer DissociationAnalytical Chemistry, 2008
- 8‐Plex quantitation of changes in cerebrospinal fluid protein expression in subjects undergoing intravenous immunoglobulin treatment for Alzheimer's diseaseProteomics, 2007
- On-Line LC−MS Approach Combining Collision-Induced Dissociation (CID), Electron-Transfer Dissociation (ETD), and CID of an Isolated Charge-Reduced Species for the Trace-Level Characterization of Proteins with Post-Translational ModificationsJournal of Proteome Research, 2007
- Implementation of Electron-Transfer Dissociation on a Hybrid Linear Ion Trap−Orbitrap Mass SpectrometerAnalytical Chemistry, 2007
- Supplemental Activation Method for High-Efficiency Electron-Transfer Dissociation of Doubly Protonated Peptide PrecursorsAnalytical Chemistry, 2006
- The utility of ETD mass spectrometry in proteomic analysisPublished by Elsevier ,2006
- Mass spectrometry-based proteomicsNature, 2003