Combined Diffusion and Perfusion MRI With Correlation to Single-Photon Emission CT in Acute Ischemic Stroke
- 1 August 1999
- journal article
- research article
- Published by Wolters Kluwer Health in Stroke
- Vol. 30 (8) , 1583-1590
- https://doi.org/10.1161/01.str.30.8.1583
Abstract
Background and Purpose —More effective imaging methods are needed to overcome the limitations of CT in the investigation of treatments for acute ischemic stroke. Diffusion-weighted MRI (DWI) is sensitive in detecting infarcted brain tissue, whereas perfusion-weighted MRI (PWI) can detect brain perfusion in the same imaging session. Combining these methods may help in identifying the ischemic penumbra, which is an important concept in the hemodynamics of acute stroke. The purpose of this study was to determine whether combined DWI and PWI in acute (Methods —Forty-six patients with acute ischemic stroke underwent DWI and PWI on days 1, 2, and 8. No patient received thrombolysis. Twenty-three patients underwent single-photon emission CT in the acute phase. Lesion volumes were measured from DWI, SPECT, and maps of relative cerebral blood flow calculated from PWI. Results —The mean volume of infarcted tissue detected by DWI increased from 46.1 to 75.6 cm 3 between days 1 and 2 ( P 3 after 1 week ( P r =0.699, P r =0.827, P r =0.824, P Conclusions —Combined DWI and PWI can predict infarct enlargement in acute stroke. PWI can detect hypoperfused brain tissue in good agreement with SPECT in acute stroke.Keywords
This publication has 25 references indexed in Scilit:
- Magnetic Resonance Imaging of Acute StrokeJournal of Cerebral Blood Flow & Metabolism, 1998
- Clinical utility of diffusion‐weighted magnetic resonance imaging in the assessment of ischemic strokeAnnals of Neurology, 1997
- High resolution measurement of cerebral blood flow using intravascular tracer bolus passages. Part I: Mathematical approach and statistical analysisMagnetic Resonance in Medicine, 1996
- High resolution measurement of cerebral blood flow using intravascular tracer bolus passages. Part II: Experimental comparison and preliminary resultsMagnetic Resonance in Medicine, 1996
- Clinical Outcome in Ischemic Stroke Predicted by Early Diffusion-Weighted and Perfusion Magnetic Resonance Imaging: A Preliminary AnalysisJournal of Cerebral Blood Flow & Metabolism, 1996
- Tissue Plasminogen Activator for Acute Ischemic StrokeNew England Journal of Medicine, 1995
- Microscopic susceptibility variation and transverse relaxation: Theory and experimentMagnetic Resonance in Medicine, 1994
- Physical performance of the Siemens MultiSPECT 3 gamma cameraNuclear Medicine Communications, 1993
- MR Contrast Due to Microscopically Heterogeneous Magnetic Susceptibility: Numerical Simulations and Applications to Cerebral PhysiologyMagnetic Resonance in Medicine, 1991
- Dynamic imaging with lanthanide chelates in normal brain: Contrast due to magnetic susceptibility effectsMagnetic Resonance in Medicine, 1988