Arthroplasty Options for the Young Patient
- 1 December 2005
- journal article
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 441 (&NA;) , 159-167
- https://doi.org/10.1097/01.blo.0000193813.08458.e2
Abstract
Our purpose was to determine whether metal femoral heads scratch with in vivo use, to characterize the scratching that occurs, and to determine whether this scratching affected polyethylene wear. Assessment of 133 consecutive retrieved femoral heads showed that metal femoral heads do scratch with in vivo use, that cobalt-chromium femoral heads are more scratch resistant than titanium alloy heads, and that scratching seems to be time dependent. Profilmetry studies showed that all roughness parameters (average roughness, maximum peak to lowest valley distance, mean peak height above the mean surface line, estimate of small peaks above the main plateau of the surface, and estimate of the depth of the valleys below the mean plateau of the surface with the exception of the symmetry of the profile about its mean line) showed increased roughness with time of use. Cobalt-chromium and Oxinium femoral heads were damaged in a dislocation model. Assessment of these femoral heads in a wear simulator revealed that against conventional polyethylene, a damaged Oxinium femoral head had no more wear than a new cobalt-chromium articulation on the same polyethylene (36.5/million cycles versus 38.4 mm/million). Against cross-linked polyethylene, a damaged Oxinium femoral head had minimal wear (1.5 mm cubed per Mc).Keywords
This publication has 39 references indexed in Scilit:
- THE OTTO AUFRANC AWARD: Highly Cross-linked Polyethylene in Total Hip ArthroplastyClinical Orthopaedics and Related Research, 2004
- Zirconia femoral head fracturesThe Journal of Arthroplasty, 2004
- Metal-on-Metal Versus Polyethylene in Hip Arthroplasty: A Randomized Clinical TrialClinical Orthopaedics and Related Research, 2003
- Wear of conventional and cross-linked ultra-high-molecular-weight polyethylene acetabular cups against polished and roughened CoCr femoral heads in a biaxial hip simulatorJournal of Biomedical Materials Research, 2002
- Advances in the processing, sterilization, and crosslinking of ultra-high molecular weight polyethylene for total joint arthroplastyBiomaterials, 1999
- Development of an extremely wear‐resistant ultra high molecular weight polythylene for total hip replacementsJournal of Orthopaedic Research, 1999
- Microstructural Investigation of the Oxide Scale on Zr-2.5NB and its Interface with the Alloy SubstrateMRS Proceedings, 1998
- The effect of surface topography of retrieved femoral heads on the wear of UHMWPE socketsMedical Engineering & Physics, 1997
- The role of counterface imperfections in the wear of polyethyleneWear, 1987
- The effect of the surface finish of alumina and stainless steel on the wear rate of UHMW polyethyleneBiomaterials, 1986